All standard current transformer ratios wholesalers & standard current transformer ratios manufacturers come from members. We doesn't provide standard current transformer ratios products or service, please contact them directly and verify their companies info carefully.
Total 93912 products from standard current transformer ratios Manufactures & Suppliers |
|
Brand Name:Chuangyin Model Number:CY-KCT01B-10 Place of Origin:China ...Current Transformer Low Consumption With Magnetic 50-300A 1.Product Introduction: The "KCT01B" Split Core Current Transformers" are designed for easy installed without the need for dismantling the primary busbar or cables. They output 5A or 1A standard secondary currents... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
Brand Name:XG Model Number:LB6-110 Place of Origin:XIAN,CHINA ...Current Tranformer LB6-110 Current transformer is oil-immersed ,Outdoor type . It can be used for the electric current measurement energy measurement and replay protection in the electric power system with a voltage of rated voltage 110kV and for requency of 50/60Hz The products are in accordance with the requirements of the standard :GB1208”Current Transformer’ and IEC60044-1’Current |
Xi'an Xigao Electricenergy Group Co., Ltd.
Shanxi |
Brand Name:HERONG ELECTRIC Model Number:JLSZW-35 Place of Origin:XI'AN CHINA ...transformer, 35KV high voltage metering box, 0.2S class The outdoor dry-type high-voltage metering box JLSZW-35 is composed of two single-phase fully insulated voltage transformers to form a three-phase "V" type connection, A and C phases are respectively connected in series with two current transformers for power lines of 35KV and below. , For electric energy metering. The current transformer... |
herong electric
Shaanxi |
Brand Name:Shinhom Model Number:SCTK660B Series Place of Origin:China ... 500mA output Current Transformer Description Split core AC current sensors have different hole sizes and current ratings to suit any application. Split core models are perfect for retrofits. Output is fixed at the industry standard . Application • Data ... |
Shaanxi Shinhom Enterprise Co.,Ltd
Shaanxi |
Brand Name:AI Model Number:CPT-3 Place of Origin:China Current Transformer CT Analyzer CT Testing Equipment Tester for current transformer: 1.Excitation curve and parameters test 2.Turns ratio test 3. Ratio and phase error test 4. Polarity mark check 5. Coil resistance measurement 6. Secondary loop burden measurement 7. Error line curve test for protection CT 8. Transient CT parameters test 9. CT nameplate guess 10.Saturation hysteresis loop curve measurement Applications of CT Current Transformer |
Advanced Instruments Co.,Limited
Chongqing |
Brand Name:GDZX Model Number:ZX-HJ Place of Origin:Hubei, China .... Parameters Rated voltage ratio: 10 kV /100V, 10/√3 kV / 100/√3V , 10/√3 kV / 100/3V Rated second capacity: 0.25VA,0.08VA,0.03VA Accuracy: 0.01, 0.02, 0.05 Voltage 80%Un-120%Un: ratio error ≤0.02%, angle erro ≤0.6’ |
Wuhan GDZX Power Equipment Co., Ltd
Hubei |
Brand Name:haofang Model Number:XRNT Place of Origin:xi'an china ...high-voltage current-limiting fuses with voltage grades ranging from 3.6 kv to 40.5 kv. Products, divided into transformer, motor and voltage transformer and capacitor protection for high-voltage current-limiting fuses and a full range of high protection, |
XI`AN HAOSHENG Electrical Equipment Manufacturing Co., Ltd.
Shaanxi |
Place of Origin:China Brand Name:OEM Model Number:PR6 ...Current Transformers PR Current Transformers Current transformer for protection requires the current to run in the circuit that carres many times of rated current, it is better than the current transformer for measurement that is restricted by many conditions. When a current transformer provides the current for the protection relay, it must guarantee its characteristics ratio... |
Hontai Machinery and equipment (HK) Co. ltd
Guangdong |
Brand Name:Shenzhen Chuangyin Model Number:JDZ12-36 Place of Origin:CHINA ...Current Transformer For Air Isolation Switchgear JDZ12-36 Epoxy resin casting and full-closed construction, Double-pole for phase-phase connection, It is widely used for measuring voltage, electric energy and auxiliary power in the sing-phase or three phase power system with the frequency 50Hz or 60Hz and highest voltage for equipment 36kV. Dear customer, Our company... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
Brand Name:XG Model Number:LZZW-10 Place of Origin:XAIN ... transformer and also used to transformer voltage or current in the circuit. However, transforming voltage and current by power transformer aims at transferring electric energy while transforming voltage and current by transformer aims at measuring and |
Xi'an Xigao Electricenergy Group Co., Ltd.
Shanxi |
Brand Name:Shinhom Model Number:SCTK Series Place of Origin:China .... The split core design permits non-contact current measurements through magnetic field induction without disconnecting cables circuits for CT installation. This method permits a safer, easier and portable current measurement. Features: Split core design, |
Shaanxi Shinhom Enterprise Co.,Ltd
Shaanxi |
Brand Name:GDZX Model Number:ZX-SBC Place of Origin:China ... of traditional transformer ratio bridge test. The screen adopts large screen high-resolution LCD, and the power supply adopts lithium battery, which is convenient for ... |
Wuhan GDZX Power Equipment Co., Ltd
Hubei |
Brand Name:Chuangyin Model Number:CYECT1-24 Place of Origin:Shenzhen ... Instrument Current Transformer for Switchgear 1 Product introduction: The products accord with standard IEC60044-8, GB/T20840.8-2007, and can meet customer’ s other special requirements. The products use Rogowski winding to test current, mainly used... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
Brand Name:XG Model Number:LB6 Place of Origin:XIAN,CHINA ....5kv 4.accuracy class: 0.2 , 0.5 , 1 , 10P , 5P10 5.Burden :from 30VA to 100VA 6.Rated primary curent : 5A to 1000A 7.Rated secondary current :5A or 1A 8.Rated insulation level : 36/70/170kv ; 40.5/80/200kv 9.Standard:IEC60044-1 2. |
Xi'an Xigao Electricenergy Group Co., Ltd.
Shanxi |
Brand Name:Chuangyin Model Number:CYECT1-36 Place of Origin:Shenzhen ...’ s other special requirement. The products use Rogowski winding to test current, mainly used in =s 35kV switchgear, match with electric instrument, digital measure and protective equipment, can at the same time realize multifunctions such as measure, |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
Brand Name:XG Model Number:LZZW... Place of Origin:XIAN ...current transformer 2. Application of cast resin ct/current transformer General Definitions General definitions have been given according to international IEC 60044. Instrument Transformer A transformer intended to supply measuring instruments meters, protection relays and other similar apparatus. Current Transformers An instrument transformer in which the secondary current... |
Xi'an Xigao Electricenergy Group Co., Ltd.
Shanxi |
Brand Name:Chuangyin Model Number:CYECT1-110D Place of Origin:Shenzhen ...Current Transformer 1 Product introduction: The products accord with standard IEC60044-8, IEC61850- 9, digital output can expediently match with the electric instrument, digital measure and protective equipment, and can meet customer’ s other special requirements. 2. Technical Data: 1. Rated primary voltage: 110 kV 2. Rated primary current... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
Brand Name:Chuangyin Model Number:CY-RCT01-80 Place of Origin:China Clamp-on Rogowski Coil Current Transformer Red/Black Flexible Power Meters General data: .Ambient operating temp:-20……+70℃ .Ambient storage temp.:-25……+75℃ .Standard Safety:IEC 61010-1:2001,600V CATⅢ Specification: unit :mm Dimensions CY-RCT01-80 CY-RCTA01... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
Brand Name:Chuangyin Model Number:CY-RCT03-305 Place of Origin:China ...Current Transformers Red/Black Power Quality Monitoring General Data: Operating temperature & humidity: 0 to 500C(32-1220F),5_80%RH(No condensate) Storage temperature & humidity: -10 to 60'C(14-1400F), ;S80%RH(No condensate) Operating environment: Indoor, altitude up to 2000 meters Standards... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
Brand Name:Chuangyin Model Number:CY-RCTTD03-190 Place of Origin:China ...Current Transformers Red/Black Power Quality Monitoring General Data: Operating temperature & humidity: 0 to 500C(32-1220F),5_80%RH(No condensate) Storage temperature & humidity: -10 to 60'C(14-1400F), ;S80%RH(No condensate) Operating environment: Indoor, altitude up to 2000 meters Standards... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |