    SpecialDieselGeneratingSet Bank

    Trace dynamic power is the corebasis of the bank of electronic technologyequipment. Banks have a large number of advanced computer technologyequipment, but only by the electronic computer is stable, reliable operation to exert its efficiency, the reliable operation must rely on the strict environmental conditions of the electronic computer room, including the room temperature, humidity, cleanliness, noise, vibration, electrostatic, the electromagnetic interference conditioncontrol precision, etc., while continuous uninterrupted power supply is the corefoundation of computerdata center.

    Product demandchallenges

    Like hospitals use diesel generating sets, but the bank has higher requirements in environment such as anti-jamming,so the stability of the performance of the diesel generator set, AMFATS function, instant startup time, low noise, low emissions, anti-interference, security,so on various aspects have stringent requirements.

    1, work conditions,

    Units can work reliably under the following conditions, the output power,can work continuously for 24 hours in the rated power output (including can overload 10% work for 1 hour every 12 hours).

    Height is not more than 1000 meters above sea level;

    Ambient temperature limit of 15C, upper limit is 40C, can choose other environmental units.

    2, low noiselow emissions

    Low noise, with enough quiet environment to ensure that the data center system securitythe bank staff to work;

    Low emissions, in order to ensure the purity of the room, to ensure that the computer systemdata security.

    3, the mainthe necessary protection

    Unit to start the battery voltage automatic detectionalarm, unit automatic delay shutdown in the following situations: low, high water temperature, water level is too low, loadthe startup fails,a corresponding signal;

    In the following situations emergency stop: high speed, short circuit, lack of phase, voltage, pressure loss, low frequency;

    In the following situations automatically send out soundlight alarm signal, low oil pressure, high water temperature, water level is too low, overload, start-up failure, speeding, short circuit, phase, frequency of high voltage,low pressure loss, start the battery voltage is too low, start the battery voltage is too high, low oil levelsets the alarm system of relay contacts;

    During starting-up mode choice for automatic start mode. Unit must have AMF (automatic) mains failure function, equipped with ATS, realizes automatic starting. < when mains power, starting time delay after 5 seconds (adjustable), can automatically start unit (a total of three continuous automatic start function), all negative switching time mains/unit as < 10 seconds, fully meet the input load time needed for less than 12 seconds, restore after the mains, unit to maintain a scale of 0-300 seconds (adjustable), automatic stop running after cooling.

    Equipped with UPS power supply system.

    4, adopts brushless permanent magnet excitation alternator, can provide higher motor starting to bear ability,the host of the output voltage waveform distortion of the stator has anti-jamming, generator can be improved with nonlinear load capacity. A stronger ability to withstand short-circuit current (up to 3 times rated current, usually lasts 10 s).

    5, stable performancehigh reliability

    The average unit failure intervals not less than 2000 hours;

    Technical performance, the unit of no-load voltage setting range is 95-105% of the rated voltage;

    To phased rectifier unit, switch power supply, UPS power supply, power supplyother load when the load is less than 50% of unit value is not going to happen when the low frequency oscillation;

    Generator can overload under rated voltage 1.5 times rated current, after 2 minutes;

    Unit with remote sensing, remoteremote control function, can in the localremote monitoring, acquisition, processing, recordingreporting relevant data of the equipment.

    Quality SpecialDieselGeneratingSet Bank for sale
    Send your message to this supplier
     
    *From:
    *To: Jiangsu Leazoom Power Machine Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2021 disqueenfrance.com. All rights reserved.