Heat Resistant Annealed 300mm2 Pvc Insulated Copper Cable

Categories PVC Insulated Cable
Brand Name: HOLD-ONE
Certification: ISO,CE,IEC,KEMA
Place of Origin: China
MOQ: 1000meter
Payment Terms: L/C, T/T, D/A, D/P, Western Union, MoneyGram
Supply Ability: 30000 Kilometer per Month
Delivery Time: Seven days
Packaging Details: Wooden drum
Model name: 1.5mm2~300mm2 PVC Insulated Cable
Conductor Type: CU
Size: 1.5mm2~300mm2
Core no.: 1 to 5
Insulation color: Customization
Sheath color: Normaly Black or red or customization
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Heat Resistant Annealed 300mm2 Pvc Insulated Copper Cable

    Copper Core PVC Insulated Flexible Cable


    We are located among the famous PVC wire manufacturers in China. The low voltage PVC cables and PVC insulated cables we provide are designed and manufactured by experts. All of our PVC cables meet the industry's required specifications. In addition, PVC insulated cables are made of aluminum and copper conductors, which comply with various international standards. In addition, our PVC cables are recognized by leading electrical consulting companies.


    Application


    Annealed copper wires with PVC insulation are suitable for connecting household appliances, small power tools, instruments and electrical lighting equipment, and are widely used as connectors for drivers, lighting, electrical equipment, instruments and telecommunications equipment.


    Technical Parameters:


    Cross SectionConductorConductor ScreenInsulationInsulation ScreenMetallic ScreenInner SheathArmourScreen Layer No.Outer SheathOverall DiameterCopper CableAluminum Cable
    mm2mmmmmmmmmmmmmmmmmmkg/kmkg/km
    508.40.810.50.80.12.00.8248689067997
    70100.810.50.80.12.10.8249099448671
    9511.50.810.50.80.12.10.82494111129375
    120130.810.50.80.12.20.824971225310059
    15014.50.810.50.80.12.30.8241011355710800
    18516.20.810.50.80.12.30.8241051505911645
    24018.40.810.50.80.12.40.8241101724912837
    30020.50.810.50.80.12.50.8251151960314061
    40023.50.810.50.80.12.60.8251222315115874
    50026.50.810.50.80.12.80.8251292704517807

    Construction details


    conductor


    The conductor is made of electrolytic grade aluminum/copper, in line with IS: 8130: 1984 Class 1 and Class 2 standards
    Insulation (IS: 5831-1984)
    PVC Type A: General insulation for fixed installation cables.
    PVC Type C: Heat-resistant (HR) insulation.


    Core recognition


    The core wire is identified by the following different colors:
    Single core: red, yellow, blue, black or any color according to customer requirements

    Two cores: red and black

    Three cores: red, yellow and blue

    Three and a half cores: red, yellow, blue and black neutral cores.

    Quad core: red, yellow, blue and black

    Five-core cable: red, yellow, blue, black and gray.

    Six nuclei and above: the two adjacent nuclei (count and direction) in each layer are blue and yellow, and the rest are gray. The same sequence as above, and the indelible printing of core numbers, or all cores of the same color have an indelible numbered contrast color on each core. Other colors agreed with purchasers and manufacturers, with digital codes.


    layout


    According to the above color scheme, stack the core wires with appropriate right-hand wires.

    Inner sheath


    According to the agreement between the supplier and the buyer to use thermoplastic materials, the laminated core is provided by wrapping or extrusion. The material used should be compatible with the temperature rating of the PVC cable.

    Armor


    Armour is provided on the inner sheath to prevent mechanical damage. Armor usually uses galvanized steel wire or steel belt. The armor should be properly left-handed on the inner sheath. The minimum coverage of the armor should be 90%. In single-core cables used in AC systems, non-magnetic hard aluminum wires should be used for armoring. If the diameter of the inner sheath does not exceed 13 mm (greater than 13 mm), round steel wire is used. Use flat steel tape armor. Different sizes of round wires can also be provided according to specific requirements.

    PVC jacket


    The outer sheath should be sheathed on the inner sheath or stacked cores. If an outer sheath is provided on the laminated core, the average thickness of the outer sheath should be the sum of the nominal thickness of the outer sheath and the minimum thickness of the inner sheath specified in IS:1554 (Part-1)-1988 The sheath specified in the standard.

    Quality Heat Resistant Annealed 300mm2 Pvc Insulated Copper Cable for sale
    Send your message to this supplier
     
    *From:
    *To: Qingdao Yilan Cable Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category:
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 disqueenfrance.com. All rights reserved.