Sign In | Join Free | My disqueenfrance.com
disqueenfrance.com
Products
Search by Category
Wholesale Marketplace
Home > Temperature Instruments >

Automatic Current And Potential Transformer Test Instrument CT PT Analyzer

Categories Electrical Test Instrument
Brand Name: AI
Model Number: BDV
Certification: ISO
Place of Origin: China
MOQ: 1 Set
Price: Negotiable
Payment Terms: T/T, Western Union, L/C
Supply Ability: 100000 sets per month
Delivery Time: 15 days
Packaging Details: Carton
Power supply: AC220V±10%, 50/60Hz±10%
Display: LCD
Test Standard: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
Voltage output: 0.1~180V (AC)
Current output: 0.001~5A(RMS)
Keyword: Current Transformer Test,Potential Transformer Instrument
Test object: current transormer and potential transformer
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Automatic Current And Potential Transformer Test Instrument CT PT Analyzer


    Current and Potentional Transformer Test Instrument CT PT Analyzer


    Test for current transformer:

    • Excitation curve and parameters test

    • Turns ratio test

    • Ratio and phase error test

    • Polarity mark check

    • Winding resistance measurement

    • Secondary loop burden measurement

    • Error line curve test for protection CT

    • Transient CT parameters test

    • CT nameplate guess

    • Saturation hysteresis loop curve measurement

    • Tests for Potencial Transformer:

    • Turns ratio test

    • Ratio error and phase angle error test

    • Polarity test

    • Secondary burden test

    • Winding resistance test


    Test for Potential Transformer

    • Secondary burden test

    • Winding resistance test

    • Polarity test

    • Turns ratio test

    • Ratio error and phase angle error test


    Applications of CT/ PT Analyzer:

    • CT nameplate check

    • CT parameters check in work burden

    • CT transient parameters analysis

    • CT ratio and phase error calibration

    • PT routine test


    Specifications:

    Item NameCurrent Transformer CT and PT Potential Transformer Tester
    Test standardsIEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
    Power supplyAC220V±10%, 50/60Hz±10%
    Voltage output0.1~180V (AC)
    Current output0.001~5A(RMS)
    Power output500VA
    Max. knee voltage measurement45KV
    Current measurementRange0~10A (automatically change range in 0.1/0.4/2/10A)
    Error<±0.1%+0.01%FS

    Voltage measurementRange0~200V (automatically change range in 1V/10V/70V/200V)
    Error< ±0.1%+0.01%FS
    Turns ratio measurement Range1~35000
    1~2000, error<0.05%
    2000~5000,error<0.1%
    5000~35000,error<0.2%
    Phase measurementerror±2min
    resolution0.01min
    Winding resistance measurementRange0~8kΩ (automatically change range in2ohm/20ohm/80ohm/800ohm/8kohm)
    Error< 0.2%RDG+0.02%FS
    Maximum resolution : 0.1mΩ
    Temperature measurement-50~100 Celsius degree; error<3 Celsius degree
    CT Secondary burdenRange0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
    Error<0.2%RDG+0.02%FS
    Maximum resolution : 0.001ohm


    PT Secondary burden
    Error0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
    Maximum<0.2%RDG+0.02%FS
    resolution0.1ohm

    PT ratio measurement

    Range
    1~35000
    1~10000 error<0.1%
    10000~35000 error<0.2%
    PT ratio error measurement :Typical error<0.05%,
    Maximum Error<0.1%
    PT phase angle measurement maximum error < 3min
    Make evaluation for test results according to selected standards
    Make word report for test result
    Make word reports one time for multi-group test records on the PC
    Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
    Compare excitation curves with saved excitation curves in the same window
    Memory capacity>1000 groups test results
    Working condition temperature-10℃~50℃; moist ≤90%

    Picture of Current And Potential Transformer Test Instrument

    Quality Automatic Current And Potential Transformer Test Instrument CT PT Analyzer for sale
    Send your message to this supplier
     
    *From:
    *To: Advanced Instruments Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category:
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们