Over / Under Current Motor Protection Relay 2 C/O Output Contacts With Fault Recording

Categories Motor Protection Relay
Brand Name: GINRI
Model Number: WDB-1Z
Certification: CE,CCC
Place of Origin: CHINA
MOQ: 10 Piece
Payment Terms: L/C, T/T, Western Union,Paypal
Supply Ability: 20000Pcs per month
Delivery Time: 1-30 days upon order quantity
Packaging Details: Voltage relay is standard seaworthy package,1pcs individual box or 5pcs in a middle box, 200pcs per carton. Base quotation is blank package. OEM design is acceptable
Rated voltage: 220VAC,380VAC ,50/60Hz
Current range: 1-10A,5-50A,10-100A,20-200A,80-400A,400-600A,600-800A
Protective functions: short-circuit, locked-rotor, overcurrent, undervurrent, phase loss, phase unbalance,overvoltage,undervoltage, earth fault
Optional functions: RS-485 communication port 4-20 mA analog output
Indicators: LED indicating voltage,current,operation status
Output contacts: 1 C/O for trip,1 C/O for alert
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Over / Under Current Motor Protection Relay 2 C/O Output Contacts With Fault Recording

    Over / Under Current Motor Protection Relay 2 C/O Output Contacts With Fault Recording


    1. The motor is easier to burn the winding than in the past because of the continuous development of the insulation technology. In the design of the motor, both the increase of output and the reduction of the volume are required, so that the heat capacity of the new type of motor becomes smaller and smaller, and the overload capacity becomes weaker and weaker; Due to the increase in the degree of automation of production, the motor is often required to operate in frequent starting, braking, reversing, and changing loads, which imposes higher requirements on the motor protection device. In addition, the application of the motor is wider. Often working in harsh environments, such as humid, high temperature, dust, corrosion and other occasions. Coupled with the non-standard motor manufacturing, equipment management oversight. All this has caused today's motors to be more easily damaged than in the past, especially overloads, short circuits, phase loss, brooms, etc.


    2. The traditional protection device has a poor protection effect. It is the traditional motor protection device that mainly includes fuses and thermal relays. Fuse is mainly used for short-circuit protection. The selection of fuse current needs to consider the starting current of the motor. Therefore, using a fuse alone to protect the motor is not desirable. Thermal relay is the most widely used motor overload protection device, but the thermal relay has low sensitivity, large error, poor stability and unreliable protection. This is precisely the fact that, although many devices have thermal relays installed, the phenomenon of motor damage that affects normal production still prevails. The traditional protection device has not yet been able to realize the motor wear monitoring, rotor eccentric monitoring products.


    ♦ Features

    -- Separate structure,LED part panel mounted and CT part screw fixing

    -- Built-in LED and keypad afford a precise,digital setting

    -- Three-phase monitoring of short-circuit, locked-rotor,overcurrent, undercurrent, phase loss, phase unbalance,overvoltage,undervoltage

    -- Earth fault (should couple with ZCT)

    -- Fault recording

    -- RS-485 communication port (optional)

    -- 4-20 mA analog output (optional)

    -- 2 C/O output contacts, one for trip,one for alert


    ♦ Protective Functions

    -- Short-circuit

    -- Locked-rotor

    -- Overcurrent

    -- Undercurrent

    -- Phase loss

    -- Phase unbalance

    -- Overvoltage

    -- Undervoltage

    -- Earth fault


    ♦ Typical Applications

    Pumps • Fans

    Blowers • Motors

    Compressors


    ♦ Technical data


    TypeWDZ-1ZWDZ-1FWDZ-1F2
    Rated voltage220VAC,380VAC ,50/60Hz
    Current range1-10A,5-50A,10-100A,20-200A,80-400A,400-600A,600-800A
    Protective functionsshort-circuit, locked-rotor, overcurrent, undervurrent, phase loss, phase unbalance,overvoltage,undervoltage, earth fault
    Optional functions

    RS-485 communication port

    4-20 mA analog output

    IndicatorsLED indicating voltage,current,operation status
    Output contacts1 C/O for trip,1 C/O for alert
    Contact capacity3A 380VAC
    Dimensions (H x W x D)118×54×135mm101×54×77mm(LED part)101×54×77mm(LED part)
    Mountingscrew fixingLED part panel mounted and CT part screw fixing

    LED part panel mounted

    and CT part rail monting


    Quality Over / Under Current Motor Protection Relay 2 C/O Output Contacts With Fault Recording for sale
    Send your message to this supplier
     
    *From:
    *To: Wenzhou Ginri Power Automation Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category:
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 disqueenfrance.com. All rights reserved.