Categories Electrical Test Equipment
Brand Name: GFUVE
Model Number: T-206
Certification: ISO9001, CE, UL
Place of Origin: BEIJING CHINA
MOQ: 1set
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 200sets
Delivery Time: 1-2weeks
Packaging Details: standard export wooden box
NAMES: Dielectric Loss Tester
KEYWORD: Anti-interference Dielectric Loss Tester
WEIGHT: 22KG
LCD: 5.7 inch black white lcd
Function: Ground protection, CVT protection, Anti misoperation,Anti - "Capacitance rise"
Accuracy: Cx: + (reading * 1%+1pF)TG Delta: + (reading * 1%+0.00040)
Test frequency: 45, 50, 55, 60, 65Hz
CVT self excitation measurement: output voltage 3 ~ 50V, output current 3 ~ 30A
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    High Voltage Anti - Interference Dielectric Loss Tester For CVT Protection

    T-206 AHigh voltage Anti-interference Dielectric Loss Tester for CVT protection, with printer

    Dielectric loss tester can effectively find the overall damp, deterioration and partly defects of electrical equipment insulation, which are widely used in electrical manufacturing, electrical equipment installation, handover and preventive testing.
    The anti-interference precision dielectric loss tester is used for on-site anti-interference, dielectric loss measurement or laboratory dielectric loss measurement. The instrument is an integrated structure with built-in dielectric loss bridge, variable variable frequency power supply, test transformer and standard capacitor, etc.. The instrument adopts frequency conversion anti-interference and Fourier transform digital filtering technology, fully automatic and intelligent measurement, and the measurement data is very stable under strong interference. The result of measurement is displayed by large screen display, and the instrument comes with micro printer to print and print test results.

    Function & Features

    • With positive / reverse wiring, internal / external standard capacitor, internal / external high voltage, reverse connection, low voltage shielding, CVT and variable ratio, and other modes of operation. Can automatically distinguish capacitance, inductance, resistance type test sample. Integrated structure, fully automatic, intelligent measurement, easy to use and carry.
    • With ordinary measurement and accurate measurement mode.Testing spped under accurate measurement mode is slower than the ordinary measurement mode, and is suitable for big interference in scene occasions. For commen scene occasions, ordinary measurement mode can be used..
    • The frequency conversion anti-interference can be measured accurately under 200% interference, and the test data is stable. It is suitable to do the anti-interference dielectric loss test on the spot.
    • By using digital waveform analysis and Bridge self calibration technology, the accuracy and stability of the positive / reverse connection are consistent. With high-precision three terminal standard capacitor, high precision dielectric loss measurement is realized.
    • Built in series and parallel dielectric loss measurement model, and can simulate voltage capacitor bridge and current comparator for convenient instrument verification.
    • During CVT self excitation magnetic measurement, the measuring line can be connected with the floor, C1/C2 can be measured at the same time to automaticly compensate the voltage sharing effect of ground busbarbar and standard capacitor, without changing line and external parts.
    • The utility model has the function of reverse connection and low voltage shielding. Under the condition of 220kV CVT ground busbarbar, the C11 can be carried out the measuring of the dielectric loss of the lower shield without disconnecting the 10kV , and simultaneously measuring the capacitance and the dielectric loss of the lower shielding part.
    • With CVT ratio measurement function, it can measure the CVT ratio, polarity and phase error.
    • Safety measures

    High voltage protection: Under condition of short circuit, breakdown or high voltage current fluctuation, it can cut off output at a high speed by short circuit mode.

    Power supply protection: incorrect connection of 380V, power supply fluctuation or sudden power failure, it will starti protection and avoid to cause over-voltage.

    Ground protection: it has the function of ground wiring detection and can not step up when it is not grounded. If the instrument is not grounded properly, the ground protection is started.

    CVT protection: four protection limits of voltage and current in high voltage, voltage and voltage and current in low voltage side to protect the equipment; the wrong menu will not output the exciting voltage. In CVT measurement without 10kV high voltage output.

    Anti misoperation: two level power switch; real-time monitoring of voltage and current; repeated key confirmation; distinctive terminal of high / low voltage; slow step-up; quick decompression; sound and light alarm.

    Anti - "Capacitance rise": when measuring large capacitance sample, the "rise" effect of voltage can occur. The instrument can automatically track the output voltage and keep the test voltage constant.

    High voltage cable: high voltage insulated wire can be used even connectting the floor.

    Anti-seismic performance: the instrument adopts unique anti-seismic design, and can withstand strong long-distance transportation, vibration and jolt without damage.

    • Print storage: instrument with a micro printer, and you can print and output the measurement results. The measurement results will be stored into the device (which can store 100 sets of measurements) or U disk for checking in the future..
    • Real time clock: instrument with real-time clock, real-time display, and can record the date and time of measurement.



    Technical Data

    Product ModelT-206
    Rated working condition

    environmental temperature: -10 ~ 50℃
    Relative humidity: <85%

    Input power180V to 270VAC, 50Hz/60Hz + 1%
    AccuracyCx: + (reading * 1%+1pF)TG Delta: + (reading * 1%+0.00040)
    Anti-interference indexfrequency conversion anti-interference, can achieve the accuracy under 200% interference
    Capacitance range

    Internal applied high voltage: 3pF ~ 60000pF/10kV 60pF to 1 mu F/0.5kV
    External applied high voltage: 3pF to 1.5 F/10kV 60pF to 30 mu F/0.5kV

    Resolutionmaximum 0.001pF, 4 bit significant digits
    TG delta rangeno limit, resolution 0.001%, capacitance, inductance, resistance, three kinds of test products, automatic identification.
    Test current range10 A to 5A
    Internal Applied high voltageset voltage range: 0.5 ~ 10kV
    Maximum output current200mA
    Lifting modecontinuous smooth adjustment
    Voltage accuracy+ (1%× readings +10V)
    Voltage resolution0.1V
    Test frequency

    45, 50, 55, 60, 65Hz single frequency
    45/55Hz, 55/65Hz, 47.5/52.5Hz automatic dual frequency conversion

    Frequency accuracy+ 0.01Hz
    External applied high voltagepositive and reverse wiring, the maximum test current 5A
    CVT self excitation measurement

    output voltage 3 ~ 50V, output current 3 ~ 30A
    C1/C2 simultaneous measurements, high-voltage wiring can be mopping

    CVT ratio measurement

    change ratio measurement accuracy: + reading×1% ratio, measuring range: 10~99999
    Phase measurement accuracy: + 0.02°
    phase measurement range: 0~ 359.99 °

    High voltage dielectric losssupport frequency conversion and vibration supply, high voltage dielectric loss
    Real time clocktime and date display in real time
    Internal storage100 sets of measurement data can be stored inside the instrument
    U disksupports U disk storage
    Printermicro thermal printer
    Computer interfaceStandard RS232 interface (optional)
    Size & weight368mm * 288mm * 280mm; main weight 22kg.
    Quality High Voltage Anti - Interference Dielectric Loss Tester For CVT Protection for sale
    Send your message to this supplier
     
    *From:
    *To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category:
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 disqueenfrance.com. All rights reserved.