Categories Ultrasonic Flow Meter
Brand Name: Iflow
Model Number: 2000F
Certification: ISO9001, CE
Place of Origin: China
MOQ: negotiable
Price: negotiable
Payment Terms: T/T, L/C, Western Union
Supply Ability: 5000 pieces per month
Delivery Time: 1-2 weeks
Packaging Details: carton / wooden case
Type: Inline Ultrasonic flow meter
Display: LCD
Transducer: inline / clamp on / insert
Accuracy: +/- 1%
Communication: 4-20 MA / OCT Pulse / Relay
Size: DN50-700
Temperature: 90 C / 160 C
Pipe material: Weld Steel, Stainless Steel, Cast Iron, Copper / Brass, Cement Pipe, Aluminum
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Residential Inline Water Flow Meter LCD Irrigation Mass Flow Measurement

    Fixed Inline ultrasonic flowmeters by transit time multi-liquid velocity determine for slurry | effluent | sewage


    General of ultrasonic flow meters

    The UFM Ultrasonic flowmeters can determine the velocity of a fluid flowing in a pipe by sound waves. When it's in no flow conditions, an ultrasonic wave's frequencies are transmitted into a pipe and its reflections from the fluid are the same. When it's under flowing conditions, the frequency of the reflected wave is different due to the Doppler effect. When liquid media moves faster, the frequency shift increases linearly. The transmitter processes signals from the transmitted wave and its reflections to determine the flow rate.

    The transit time type ultrasonic flowmeters can give and receive ultrasonic waves between the transducers in both the upstream and downstream in the pipe. While it's under no flow conditions, it takes the same time to travel upstream and downstream between the transducers. While it's under flowing conditions, the upstream wave will travel slower and take more time than the (faster) downstream wave. When the fluid moves faster, the difference between the upstream and downstream times increases. The transmitter processes upstream and downstream times to determine the flow rate.


    Data sheet

    Accuracy <1%

    Flow rate 0 - 10m/s, bi-direction

    Pipe diameter DN32 - DN6000 mm

    Liquid temperature -30℃ - 160℃

    Liquid type water, sea water, sewage, effluent, oil, alcohol, any single liquid that can

    transmit ulstrasonic wave

    Pipe material stainless steel, cast iron, copper, PVC, aluminum, fiber glass steel

    Output one way 4-20mA, one way OCT pulse, one way replay

    Input three way 4-20mA, PT1000 platinum resistor for heat measurement

    Communication RS485, MODBUS

    Data storage SD card

    Power supply DC8-36V / AC85-264V

    Protection IP65 (main body), IP68 (transducer)

    Humidity <85% RH

    Ambient temperature -20℃ - 60℃


    Description:

    The ultrasonic flowmeter is available with pipe type, clamp on and other options, it's designed for linear and bi-directional volumetric flow measurement of liquid. The measured flow datas can be output by standard analog or pulse or frequency. Through HMI user friendly operator interface, the unit can be set up for a wide range of applications. Next to actual volumetric flow measurement, the unit can be configured to perform flow totalization ( plus, minus, or sum). Measurement and output of the liquid sonic velocity can be configured too.


    Optionally the unit can be set to perform one of the following additional functions:

    • Calculate and output corrected standard volumetric or mass flow using external pressure & temperature inputs
    • Batch function
    • Heat function, combining T1, T2 and volume

    Metering Diagram

    Flow measurement Heat measurement

    Fixed Inline Ultrasonic Flowmeters By Transit Time Multi - Liquid Velocity Determine

    Reference chart

    TypeModelPipe dia (mm)TemperatureDimension (mm)
    Clamp onTS-2DN15-100-30-90℃45x25x32
    TM-1DN50-700-30-90℃64x39x44
    TL-1DN300-6000-30-90℃97x54x53
    Clamp on (high temperature)TS-2-HTDN15-100-30-90℃45x25x32
    TM-1-HTDN50-700-30-90℃64x39x44
    TL-1-HTDN300-6000-30-90℃97x54x53
    Insertion typeTC-1DN80-6000-30-90℃190x80x55
    TC-2(lengthen)DN80-6000-30-90℃335x80x55
    Pipe typeG3 (π type)DN15-25-30-160℃
    G2DN32/DN40-30-160℃
    G3DN50-6000-30-160℃

    Optional temperature transducer

    SpecificationModelDiaTemp.Water cutAccuracy
    Clamp-on temp. transducer Pt100CT-1>DN50-40-160℃No100+ 0.8℃
    Insertion temp. Transducer Pt100TCT-1Yes
    Insertion temp. Pt100 with pressurePCT-1No
    Insertion temp.Pt100 for small pipe DSCT-1<DN50Yes

    Industries

    • Chemicals
    • Petrochemicals
    • Oil & Gas
    • Heating, Ventilation & Air Conditioning (HVAC)
    • Power Plants
    • Water treatment

    Liquid type

    • Metering of cooling water
    • Demineralisedwater
    • Control of batching and blending operations
    • Mass flow measurement
    • Allocation measurement
    • District heating
    • Irrigation
    • Energy measurement

    Model Selection

    IModel
    YFElectromagnetic flowmeter
    TFTurbine
    VFVotex
    LXVane wheel
    TUltrasonic
    E/F display modeE: compact/local display, F: remote display
    Pipe DiaType (mm)
    xxxx

    10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300,

    400, 500, 600, 800, 1000

    CodeAccuracy
    1+ 0.5% FS
    2+ 1.0% FS
    3+ 0.2% FS
    CodeType
    NConverter: 12 / 24 VDC, pulse output
    ATransmitter: 24VDC, 4-20mA outpt
    BIntelligent, Lion battery, no local display
    GSmart, local display, 4-20mA output
    C1Smart, local display, RS485
    C2Smart, local display, HART
    CodeType
    SCarbon steel housing
    LStainless steel housing
    GHigh pressure housing
    HL316L electrode
    HTiTitanium electrode
    HTaTantlum electrode
    HCHastelloy-C electrode
    L1Liquid media
    L2Gas media
    PPressure compensation
    TTemperature compensation
    PTPressure&Temp. Compensation
    FPTFE liner
    XRubber liner

    Sample: IYF-E-0100-1-C1-S-HL-L1-F,

    Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt,

    RS485, 316L electrode, liquid media meter, PTFE liner


    Competitive Advantage:

    • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
    • CE approval
    • Strict process control
    • Advanced calibration equipment
    • Engineer team
    Quality Residential Inline Water Flow Meter LCD Irrigation Mass Flow Measurement for sale
    Send your message to this supplier
     
    *From:
    *To: Shanghai I Fluid Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category:
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 disqueenfrance.com. All rights reserved.