Brand Name: Lanry
Model Number: TF1100-EI
Certification: ISO9000, CE, CPA,CMC
Place of Origin: Shanghai, China (Mainland)
MOQ: 1 Unit/Units
Price: Negotiable
Supply Ability: 1000 Unit/Units per
Packaging Details: packing: 1unit/carton
Flow velocity range: 0.01~12m/s bi-directional
Resoulution: 0.25mm/s
Pipe diameter: DN20-DN6000
Application: Measuring Fluid
Sensitivity: 0.003m/s
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

DN65 To DN6000mm Insertion Ultrasonic Flow Meter

Hot-tapped installation transit-time Ultrasonic Flowmeter for DN65-6000mm pipe size
The transit-time tube plug-in ultrasonic flowmeter adopts the transit-time working principle. It effectively solves the problems that the inner wall of the pipe is scaled, the pipe is obsolete, and the pipe is not sound-conducting materials. The plug-in sensor comes with a shut-off ball valve, which is convenient and fast for installation and maintenance without shutting off or breaking the pipe. For special pipes whose materials cannot be drilled and whose surface is not smooth, the sensor can also be installed by installing a hoop. In addition, it is also equipped with an optional heat (cold) metering function to perform a complete heat analysis. Because of its fast installation and simple operation, it is an ideal flow measurement instrument product for production monitoring, water balance debugging, heating network balance debugging, and energy saving monitoring. .
Hot-tapped installation transit-time Ultrasonic Flowmeter for DN65-6000mm pipe size Features:
1. No moving parts, no pressure drop, no maintenance
2. For commonly used pipe materials and diameters from 20mm to over 6.0m.
3. Data logger function for insertion ultrasonic flow meter
4. Thermal energy measurement capability can be optional.
5. High temp. Insertion transducers

6. Wide bi-directional flow range of 0.01 m/s to 12 m/s..


Application

General

● Support of commissioning process and installation

● Performance and efficiency measurement

● Service and maintenance

● Replacement of defective devices
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves

● Energy efficiency audits

Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Refrigeration and air conditioning systems

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry
Food , beverage and pharmaceutical industry

Specifications:Transmitter

Measurement principleUltrasonic transit-time difference correlation principle
Flow velocity range0.01 to 12 m/s, bi-directional
Resolution0.25mm/s
Repeatability0.2% of reading
Accuracy±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time0.5s
Sensitivity0.003m/s
Damping of displayed value0-99s(selectable by user)
Liquid Types Supportedboth clean and somewhat dirty liquids with turbidity <10000 ppm
Power SupplyAC: 85-265V DC: 24V/500mA
Enclosure typeWall-mounted
Degree of protectionIP66 according to EN60529
Operating temperature-20℃ to +60℃
Housing materialFiberglass
Display4 line×16 English letters LCD graphic display, backlit
UnitsUser Configured (English and Metric)
RateRate and Velocity Display
Totalizedgallons, ft³, barrels, lbs, liters, m³,kg
Thermal energyunit GJ,KWh can be optional
Communication4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data
Weight2.4kg

Specifications:Transducer


Degree of protectionIP67 or IP68 according to EN60529
Suited Liquid TemperatureStd. Temp.: -35℃~85℃
High Temp.: -35℃~150℃
Pipe diameter rangeDN65-6000
Transducer SizeType S Φ58*199mm
Material of transducerStainless Steel
Cable LengthStd: 10m
Temperature SensorPt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%


Packing & Delivery


Insertion flow meters liquid measurement TF1100-EI wall mounted transit time type


With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.

Delivery

Insertion flow meters liquid measurement TF1100-EI wall mounted transit time type

Standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea can be optional.

Quality DN65 To DN6000mm Insertion Ultrasonic Flow Meter for sale
Send your message to this supplier
 
*From:
*To: Lanry Instruments (Shanghai) Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0