Insertion Type Transit Time Ultrasonic Flow Meter For Waste Water Industry

Categories Transit Time Ultrasonic Flow Meter
Brand Name: Lanry
Model Number: TF1100-EI
Certification: CE
Place of Origin: Shanghai, China (Mainland)
MOQ: 1 Unit
Price: Negotiable
Supply Ability: 100unit/week
Packaging Details: Carton Packing
Product Name: Inserted Type Ultrasonic Flow Meter
Output: Datalogger/4-20mA /OCT /RS485/RS232/GPRS
Accuracy: Reading+/- 1%
Transducer range: DN20-DN6000
Application: Measuring Liquids
Power supply: 85~265VAC
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Insertion Type Transit Time Ultrasonic Flow Meter For Waste Water Industry

Insertion type ultrasonic flow meter TF1100-EI for waste water industry
Insertion type ultrasonic flow meter TF1100-EI is widly used in many fileds, such as water and waste water industry - hot water, cooling water, potable water, sea water etc., chemical industry, petrochemical industry and so on.
Insertion type ultrasonic flow meter TF1100-EI provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.
Insertion type ultrasonic flow meter TF1100-EI for waste water industry Features:
1. Hot-tapped installation, no pipe line flow interrupted
2. Thermal energy measurement capability can be optional.
3. Wide bi-directional flow range of 0.01 m/s to 12 m/s..
4. Wide liquid temperature range: -35℃~200℃.
5. For commonly used pipe materials and diameters from 20mm to over 6.0m.

6. Data logger function for insertion ultrasonic flow meter


Application

General
● Service and maintenance

● Energy efficiency audits

● Replacement of defective devices

● Support of commissioning process and installation

● Performance and efficiency measurement
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry

Refrigeration and air conditioning systems
Food , beverage and pharmaceutical industry

Metallurgy and mining applications

Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

Specifications:Transmitter


Measurement principleUltrasonic transit-time difference correlation principle
Flow velocity range0.01 to 12 m/s, bi-directional
Resolution0.25mm/s
Repeatability0.2% of reading
Accuracy±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time0.5s
Sensitivity0.003m/s
Damping of displayed value0-99s(selectable by user)
Liquid Types Supportedboth clean and somewhat dirty liquids with turbidity <10000 ppm
Power SupplyAC: 85-265V DC: 24V/500mA
Enclosure typeWall-mounted
Degree of protectionIP66 according to EN60529
Operating temperature-20℃ to +60℃
Housing materialFiberglass
Display4 line×16 English letters LCD graphic display, backlit
UnitsUser Configured (English and Metric)
RateRate and Velocity Display
Totalizedgallons, ft³, barrels, lbs, liters, m³,kg
Thermal energyunit GJ,KWh can be optional
Communication4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data

Specifications:Transducer


Degree of protectionIP67 or IP68 according to EN60529
Suited Liquid TemperatureStd. Temp.: -35℃~85℃
High Temp.: -35℃~150℃
Pipe diameter rangeDN65-6000
Transducer SizeType S Φ58*199mm
Material of transducerStainless Steel
Cable LengthStd: 10m
Temperature Sensor

Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%



Packing & Delivery


Inserted Type Ultrasonic Flow Meter With 4-20mA Output for clean liquid application


With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.

Delivery

Inserted Type Ultrasonic Flow Meter With 4-20mA Output

Standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea can be optional.

Quality Insertion Type Transit Time Ultrasonic Flow Meter For Waste Water Industry for sale
Send your message to this supplier
 
*From:
*To: Lanry Instruments (Shanghai) Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0