Sign In | Join Free | My disqueenfrance.com |
|
Categories | Power Distribution Cabinet |
---|---|
Brand Name: | SUNTREE |
Model Number: | SQ3 |
Certification: | iec ce |
Place of Origin: | Zhejiang, China |
MOQ: | 10 |
Price: | 25~600usd |
Payment Terms: | MoneyGram |
Supply Ability: | 10000 Piece/Pieces per Month |
Packaging Details: | standard carton packing |
Operation: | Electric Type |
Installation: | Fixed |
Speed: | Normal Type Circuit Breaker |
Structure: | Conventional Circuit Breaker |
Arc-Extinguishing Medium: | Air |
Max. Voltage: | 690V |
Temperature: | -25 to 55 |
Pole: | 3 Pole 4 Pole |
Types | Carton Size | GW/ Carton | NW/ Carton | QTY/ carton | ||
L | W | H | ||||
ATS SQ3-63/4P 63A | 0.485 | 0.31 | 0.28 | 17.53 | 15.53 | 8 |
ATS SQ3-100/4P 100A | 0.35 | 0.26 | 0.30 | 15 | 14 | 2 |
ATS SQ3-225/4P 225A | 0.40 | 0.26 | 0.33 | 19 | 18 | 2 |
ATS SQ3-400/4P 400A | 0.58 | 0.38 | 0.24 | 25 | 24 | 1 |
ATS SQ3-630/4P 630A | 0.67 | 0.38 | 0.24 | 33 | 32 | 1 |
Normal working conditions
Ambient temperature: -5~+40ºC, and the average temperature in 24
hours below +35ºC(except for special orders).
Elevation of installation site: 2000m
Relative humidity: not exceeding 50% at the maximum ambient
temperature of +40ºC.
With lower temperature, higher humidity would be permitted, but the
lowest average temperature in a month not exceeding 90% in
that month, andgiving consideration to the dews on the goods
surface, which would appear due to temperature change.
Pollution protection: 3 grade
The breaker should be put in the place where there isn't any
explosive medium and conductive dust and no gas, which would
corrode metal or destroy theinsulation.
Structure and properties
SQ3 is a critical component of any emergency or standby power
system. When thenormal (preferred) source of power is lost, a
transfer switch quickly and safely shifts the load circuit from the
normal source of power to the emergency (alternate) source of
power. This permits critical loads to continue running with minimal
or no outage. After the normal source of power has been restored,
the re-transfer process returns the load circuit to the normal
power source.
1) The setting is formed with two sets of power-operated operation
mechanism circuit breakers and mechanical interlocking, fuse,
wiring
terminal.
2) Two-set circuit breakers have electric interlocking and
mechanical interlocking double protections to prevent the two-set
circuit
breaker close on at the same time.
3) The setting suits for 220V working voltage (circuit breaker
rated working voltage), control the power pass the case, frame
board
control pushbutton (user self-prepared and connect to) direct
control two sets power operated operation mechanism to carry out
the power reliable switch over.
4) Suitable for general manual work control occasion, simple
structure, low cost.
Certificate
![]() |