Sign In | Join Free | My disqueenfrance.com
disqueenfrance.com
Products
Search by Category
Wholesale Marketplace
Home > Network Switches >

100gbase Lr4 Qsfp28 Duplex Lc 10km Fiber Optic Transceiver

Categories Fiber Optic Transceiver
Brand Name: Sopto
Model Number: SPT-QSFP28-LR4/SPT-QSFP28-LR4-M
Certification: CE RoHS FCC
Place of Origin: Shenzhen China
MOQ: 1pcs
Payment Terms: L/C, T/T,Paypal, D/P
Supply Ability: 10000 pcs per month
Delivery Time: 5-8 days
Packaging Details: 10pcs standard boxes, mass order with carton box package can do OEM according to customer's request.
Wavelength: 1310nm
Product name: fiber optic transceiver,100g qsfp28
Connector: LC
Transmission distance: 10km
Application: FTTH FTTB FTTX Network,Telecommunication
Date rate: 100Gbps
Power supply: 3.135~3.465V
Operating temperature: Commercial 0 to 70
Lead time: 3-7working days
Package type: qsfp28
MOQ: 1pcs
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

100gbase Lr4 Qsfp28 Duplex Lc 10km Fiber Optic Transceiver

100gbase Lr4 Qsfp28 Duplex Lc 10km Fiber Optic Transceiver


Descriptions of 100G QSFP28 module


This product is a 100Gb/s transceiver module designed for optical communication applications compliant to 100GBASE-LR4 of the IEEE P802.3ba standard. The module converts 4 input channels of 25Gb/s electrical data to 4 channels of LAN WDM optical signals and then multiplexes them into a single channel for 100Gb/s optical transmission. Reversely on the receiver side, the module de-multiplexes a 100Gb/s optical input into 4 channels of LAN WDM optical signals and then converts them to 4 output channels of electrical data.

The central wavelengths of the 4 LAN WDM channels are 1295.56, 1300.05, 1304.58 and 1309.14 nm as members of the LAN WDM wavelength grid defined in IEEE 802.3ba. The high performance cooled LAN WDM EA-DFB transmitters and high sensitivity PIN receivers provide superior performance for 100Gigabit Ethernet applications up to 10km links and compliant to optical interface with IEEE802.3ba Clause 88 100GBASE-LR4 requirements.

The product is designed with form factor, optical/electrical connection and digital diagnostic interface according to the QSFP+ Multi-Source Agreement (MSA). It has been designed to meet the harshest external operating conditions including temperature, humidity and EMI interference.


Functional Description


The transceiver module receives 4 channels of 25Gb/s electrical data, which are processed by a 4-channel Clock and Data Recovery (CDR) IC that reshapes and reduces the jitter of each electrical signal. Subsequently, each of 4 EML laser driver IC's converts one of the 4 channels of electrical signals to an optical signal that is transmitted from one of the 4 cooled EML lasers which are packaged in the Transmitter Optical Sub-Assembly (TOSA). Each laser launches the optical signal in specific wavelength specified in IEEE802.3ba 100GBASE-LR4 requirements. These 4-lane optical signals will be optically multiplexed into a single fiber by a 4-to-1 optical WDM MUX. The optical output power of each channel is maintained constant by an automatic power control (APC) circuit. The transmitter output can be turned off by TX_DIS hardware signal and/or 2-wire serial interface.

The receiver receives 4-lane LAN WDM optical signals. The optical signals are de-multiplexed by a 1-to-4 optical DEMUX and each of the resulting 4 channels of optical signals is fed into one of the 4 receivers that are packaged into the Receiver Optical Sub-Assembly (ROSA). Each receiver converts the optical signal to an electrical signal. The regenerated electrical signals are retimed and de-jittered and amplified by the RX portion of the 4-channel CDR. The retimed 4-lane output electrical signals are compliant with IEEE CAUI-4 interface requirements. In addition, each received optical signal is monitored by the DOM section. The monitored value is reported through the 2-wire serial interface. If one or more received optical signal is weaker than the threshold level, RX_LOS hardware alarm will be triggered.

A single +3.3V power supply is required to power up this product. Both power supply pins VccTx and VccRx are internally connected and should be applied concurrently. As per MSA specifications the module offers 7 low speed hardware control pins (including the 2-wire serial interface): ModSelL, SCL, SDA, ResetL, LPMode, ModPrsL and IntL.

Module Select (ModSelL) is an input pin. When held low by the host, this product responds to 2-wire serial communication commands. The ModSelL allows the use of this product on a single 2-wire interface bus – individual ModSelL lines must be used.

Serial Clock (SCL) and Serial Data (SDA) are required for the 2-wire serial bus communication interface and enable the host to access the QSFP28 memory map.

The ResetL pin enables a complete reset, returning the settings to their default state, when a low level on the ResetL pin is held for longer than the minimum pulse length. During the execution of a reset the host shall disregard all status bits until it indicates a completion of the reset interrupt. The product indicates this by posting an IntL (Interrupt) signal with the Data_Not_Ready bit negated in the memory map. Note that on power up (including hot insertion) the module should post this completion of reset interrupt without requiring a reset.

Low Power Mode (LPMode) pin is used to set the maximum power consumption for the product in order to protect hosts that are not capable of cooling higher power modules, should such modules be accidentally inserted.

Module Present (ModPrsL) is a signal local to the host board which, in the absence of a product, is normally pulled up to the host Vcc. When the product is inserted into the connector, it completes the path to ground through a resistor on the host board and asserts the signal. ModPrsL then indicates its present by setting ModPrsL to a “Low” state.

Interrupt (IntL) is an output pin. “Low” indicates a possible operational fault or a status critical to the host system. The host identifies the source of the interrupt using the 2-wire serial interface. The IntL pin is an open collector output and must be pulled to the Host Vcc voltage on the Host board.



Features of 100G QSFP28 module


● Hot pluggable QSFP28 MSA form factor

● Compliant to IEEE 802.3ba 100GBASE-LR4

● Up to 10km reach for G.652 SMF

● Single +3.3V power supply

● Operating case temperature: 0~70℃

● Transmitter: cooled 4x25Gb/s LAN WDM EML TOSA (1295.56, 1300.05, 1304.58, 1309.14nm)

● Receiver: 4x25Gb/s PIN ROSA

● 4x28G Electrical Serial Interface (CEI-28G-VSR)

● Maximum power consumption 4.0W

● Duplex LC receptacle


Applications


● 100GBASE-LR4 Ethernet Links

● Infiniband QDR and DDR interconnects

● Client-side 100G Telecom connections


Specifications


Product NO.SPT-QSFP28-LR4/SPT-QSFP28-LR4-M
Wavelength1310nm
Product name100g qsfp28 module
Transmission Distance10km
Operating temperatureStandard: 0 to +70°C
Date rate100Gbps
ConnectorDuplex LC
Power supplySingle 3.135~3.465V
Package TypeQSFP28

Optical Characteristics


ParameterSymbolMinTypicalMaxUnitNotes
Lane WavelengthL01294.531295.561296.59nm
L11299.021300.051301.09nm
L21303.541304.581305.63nm
L31308.091309.141310.19nm
Transmitter
SMSRSMSR30dB
Total Average Launch PowerPT10.5dBm

Average Launch Power,

each Lane

PAVG-4.34.5dBm
OMA, each LanePOMA-1.34.5dBm1
Difference in Launch Power between any Two Lanes (OMA)Ptx,diff5dB
Launch Power in OMA minus Transmitter and Dispersion Penalty (TDP), each Lane-2.3dBm
TDP, each LaneTDP2.2dB
Extinction RatioER4dB
RIN20OMARIN-130dB/Hz
Optical Return Loss ToleranceTOL20dB
Transmitter ReflectanceRT-12dB
Eye Mask{X1, X2, X3, Y1, Y2, Y3}{0.25, 0.4, 0.45, 0.25, 0.28, 0.4}2
Average Launch Power OFF Transmitter, each LanePoff-30dBm
Receiver
Damage Threshold, each LaneTHd5.5dBm3
Total Average Receive Power10.5dBm
Average Receive Power, each Lane-10.64.5dBm
Receive Power (OMA), each Lane4.5dBm
Receiver Sensitivity (OMA), each LaneSEN-8.6dBm
Stressed Receiver Sensitivity (OMA), each Lane-6.8dBm4
Difference in Receive Power between any Two Lanes (OMA)Prx,diff5.5dB
LOS AssertLOSA-18dBm
LOS DeassertLOSD-15dBm
LOS HysteresisLOSH0.5dB
Receiver Electrical 3 dB upper Cutoff Frequency, each LaneFc31GHz
Conditions of Stress Receiver Sensitivity Test (Note 5)
Vertical Eye Closure Penalty, each Lane1.8dB
Stressed Eye J2 Jitter, each Lane0.3UI
Stressed Eye J9 Jitter, each Lane0.47UI

Mechanical Dimensions



Ordering Informations


Part NumberProduct Description
SPT-QSFP28-LR4100G BASE-LR4 QSFP28 Module Duplex Lc 10km Fiber Optic Transceiver
SPT-QSFP28-LR4-M100G BASE-LR4 QSFP28 Module Duplex Lc 10km Fiber Optic Transceiver Extinction Ratio=8
Quality 100gbase Lr4 Qsfp28 Duplex Lc 10km Fiber Optic Transceiver for sale
Send your message to this supplier
 
*From:
*To: Shenzhen Sopto Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Find Similar Products By Category:
Inquiry Cart 0