Sign In | Join Free | My disqueenfrance.com
disqueenfrance.com
Products
Search by Category
Wholesale Marketplace
Home > Transformers >

Precision Current Transformer Analyzer / Power Transformer Testing Equipment

Categories CT PT Analyzer
Brand Name: GFUVE
Model Number: GF106T
Certification: GB1207-2006, GB1208-2006, GB16847-1997 IEC60044-1, IEC60044-6, IEC61869-2-2012
Place of Origin: China
MOQ: 1
Payment Terms: T/T, Western Union
Supply Ability: 200
Delivery Time: 1-2week
Packaging Details: Standard Wooden Case
Accuracy: 0.2%, 0.5%
Power supply: AC 220V±10% or AC 110V±10%, 50/60Hz
Excitation voltage output: 0-2500Vrms,
Excitation current output: 0-5Arms (20A peak-value)
Large current output: 0-1000A
DC resistance measurement Range: 0.1-300Ω
DC resistance measurement Accuracy: ≤0.5% (0.2%RD+0.3%RG)
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Precision Current Transformer Analyzer / Power Transformer Testing Equipment

CT PT Analyzer GF106T


Ct/Pt Analyzer/Instrument Transformer Testing/Ta/Tv Analyzer /Pt Test System


I. Current Transformer (CT)II. Voltage Transformer (PT)
1. Magnetization curve1. Excitation characteristic test
2. Transformation ratio test2. Transformation ratio test
3. Polarity3. Polarity
4. 5% and 10% error curve4. Withstand test of power frequency alternating current
5. Current Injecting5. Degauss
6. Degauss6. Calculation of knee point value
7. Withstand test of power frequency alternating current7. Actual secondary load test 
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test 
10. Resistance test 

PARAMETERS

Electrical parameters
Accuracy0.2%, 0.5%
Power supplyAC 220V±10% or AC 110V±10%, 50/60Hz
Excitation voltage output0-2500Vrms,
Excitation current output0-5Arms (20A peak-value)
Large current output0-1000A
Electrical parameters - continued
Accuracy≤0.5% (0.2%RD+0.3%RG)
Secondary winding DC resistance measurementRange0.1-300Ω
Accuracy≤0.5% (0.2%RD+0.3%RG)
Secondary actual load measurementRange5VA-1000VA
Accuracy≤0.5% (0.2%RD+0.3%RG)±0.1VA
CT/PT phase error measurementAccuracy±4min
Resolution0.01min
CT ratio error measurementRange≤25000A/5A(5000A/1A)
Accuracy≤0.5%
PT ratio error measurementRange1-500KV
Accuracy≤0.5%
Standards 
Reference standardsGB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2-2012
Safety standardsGB 4793.1-2007
EMCEMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters 
Overall dimension (L x W x H) (mm)400 x 250 x 250
Weight (kg)≤22
Environmental conditions 
Relative humidity90RH%
Operating temperature-10°C to +40°C
Altitude≤1000m
Quality Precision Current Transformer Analyzer / Power Transformer Testing Equipment for sale
Send your message to this supplier
 
*From:
*To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0