Sign In | Join Free | My disqueenfrance.com
disqueenfrance.com
Products
Search by Category
Wholesale Marketplace
Home > Industrial Controls >

HbA1C Analyzer Ues Glycosylated Hemoglobin (HbA1c) Calibrator LD-500 Fully Automatic HbA1c Analyzer Test Use

Categories HPLC HbA1c Analyzer
Brand Name: LABNOVATION
Place of Origin: Shenzhen, China
Payment Terms: D/A, D/P, T/T
Delivery Time: 5-7 work day
Packaging Details: Carton
Shelf Life: 12 Months
Storage Temp: 2-8℃
Application: LD-500,LD-600
Sunshine: Not Allowed
Name: Hemoglobin A1c Analyzer
ODM: yes
Certification: IFCC, NGSP, CE
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

HbA1C Analyzer Ues Glycosylated Hemoglobin (HbA1c) Calibrator LD-500 Fully Automatic HbA1c Analyzer Test Use

HbA1C Analyzer Ues Glycosylated Hemoglobin (HbA1c) Calibrator LD-500 Fully Automatic HbA1c Analyzer Test Use


Package Specification

There are two concentrations: Level 1 (low) and Level 2 (high)

Level 10.1mL×30.1mL×40.1mL×61mL×60.5mL×6
Level 20.1mL×30.1mL×40.1mL×61mL×60.5mL×6

Application

Calibrate glycosylated hemoglobin system in HbA1c analyzer

Storage And Validation

  • Stable at 2℃ – 8℃ for 12 months, direct exposure to sunshine avoided.
  • Stable for 7 days at 2℃ – 8℃ after open-vial.

Preparation For Use

  • 1. Open the vial carefully, avoiding any loss of material.
  • 2. Reconstitute by pipetting exactly 100ul of distilled water at +15°C to +25°C, into the vial.
  • 3. Close the rubber stopper and leave to stand for 10 to 15 minutes out of bright light before use.
  • 4. Swirl gently several times during the reconstitution period to ensure that the contents are completely dissolved.
  • 5. Prior to use, mix the contents by inverting the vial. Do not shake the vial as the formation of foam should be avoided. Ensure that no lyophilized material remains unreconstituted.
  • 6. Please close the rubber stopper after drawing the sample and put in the refrigerator soon to avoid containment and evaporation.

Cautions

  • Store per request and use it within the validation. The reagent out of validation should be dealt with in experimental waste way.
  • Different reagents with different lots can’t be cross used.
  • Reagent box is for IVD use only and obey the laboratory SOP.
Quality HbA1C Analyzer Ues Glycosylated Hemoglobin (HbA1c) Calibrator LD-500 Fully Automatic HbA1c Analyzer Test Use for sale
Send your message to this supplier
 
*From:
*To: Labnovation Technologies, Inc.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0