High Utilization Precision Air Handling Units For Server Rooms Equipment

Categories Precision Air Conditioning Units
Brand Name: Coolent
Model Number: T56,T61,T70,T80,T90
Certification: ISO/CE
Place of Origin: China
MOQ: 1
Price: to be Negotiated
Payment Terms: T/T
Supply Ability: 1000/Month
Delivery Time: 4W
Packaging Details: WOODEN
Cooling capacity: 50-70KW
Mounting: On Floor Standing
Condition: Brand New
Type: Precision air conditioning unit( air cooled/water cooled )
Voltage: 380/400 VAC,230 VAC,220V
Warranty: 1 Year(12 month )
Name: PAC cooling unit
Refrigerant: R22(R407C/R410A)
Application: Computer Room,Printing factory/cinema/supper marekt/restaurant/Offfice/Kindergarten,Industrial,Heat recovery,adjust cold/heat/humidity
Color: Black/Grey
Power: 3N-380V-50Hz,220v/50hz/60hz
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

High Utilization Precision Air Handling Units For Server Rooms Equipment

High Utilization Precision Air Handling Units For Server Rooms Equipment


Product Introduction

Coolnet precision air conditioners can precisely control the new energy and performance standards of data centers, server rooms and communication networks, as well as the temperature and humidity of computer rooms with low PUE target requirements, for high reliability, better humidity and temperature settings, and part load efficiency. Ensure the smooth operation of the equipment in the computer room, ensure the service life of the equipment, and reduce the company's maintenance costs.


Benefits

Applications

  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber

Technical Features

Precise and reliable
Careful design, strict laboratory testing and comprehensive quality control ensure the unit has excellent reliability;The unit uses parts of world-renowned brands to ensure the high reliability and service life of the whole machine.
Energy saving and high efficiency


Energy saving and high efficiency
Save a lot of energy consumption in a reasonable and feasible way, and make full use of natural resources;
The unit uses a high-efficiency fan and a fully enclosed compressor system to reduce operating costs and always pay attention to energy efficiency.


Multiple air supply
The air supply method of the air-conditioned room depends on the source and distribution characteristics of the heat in the room. According to the dense arrangement of equipment in the computer room, the number of cables and bridges, and the wiring method, the air supply method of the air conditioner is divided into lower delivery, upper return, top feed back, top feed side back, side feed side back.


Static pressure box air supply
The air conditioner in the computer room usually does not use pipes, but uses the space at the lower part of the raised floor or the upper part of the ceiling as the return air of the static pressure box. static pressure is equal.




Technical Parameters


Model: CYAT26D/UT31D/UT35D/UT41D/UT45D/UT50D/UT55D/UT61D/UT70D/UT76D/UT85D/UT90D/UT100D/U
Power Supply380V 3Ph-50HZ
Air DischargeUpflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1)KW26.931.935.941.945.350.555.461.470.576.285.590.8102
SensibleKW24.829.533.138.842.547.851.657.565.271.279.584.595.7
AEERW/W3.63.63.63.63.63.73.73.63.63.63.63.63.6
Air Flowm3/h800095001000011500130001550016000175001850020500225002350024200
Compressor Hermetic scroll
RefrigerantR407C
Compressor quantityPC2222222222222
Fan Section Centrifugal fan (Optional EC)
Fan quantityPC2222222223333
Rated currentA4.34.34.34.44.44.455.25.26.516.516.516.5
Rated powerW1600160018001800200020003000330039003900540063006300
Total heating capacityKW66699999912121212
MaterialPTC
Humidifier Section Electrode type
CapacityKg/h5555131313131313131313
Rated CurrentA6666151515151515151515
Condenser Model2*582*582*582*582*802*802*1002*1002*1202*1502*1502*1652*180