Sign In | Join Free | My disqueenfrance.com
disqueenfrance.com
Products
Search by Category
Wholesale Marketplace
Home > Oxide >

OLED Window 0.01~100NTU Laser Turbidity Electrode For Water Provide project

Categories Turbidity Analyzer
Brand Name: Daruifuno
Model Number: OLTU602-0MDO1A
Certification: CE, ISO
Place of Origin: China
MOQ: 1
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 10000 Sets per Month
Delivery Time: 5-25 days
Packaging Details: Carton
Product Name: Lazer Turbidity Sensor
Measuring Range: 0.01~100NTU 0.1~50℃
Light Source: 660nm laser light source
Operating Environment: 0~45℃
Flow Rate: 100ml/min≤x≤500ml/min
Calibration: Standard solution/water sample/zero point calibration
Working Instructions: OLED window
Sample liquid Level: No judgment
Sample Emptying/Blowdown: Not equipped
Waterproof Level: IP66
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

OLED Window 0.01~100NTU Laser Turbidity Electrode For Water Provide project

OLED Window 0.01~100NTU Laser Turbidity Electrode For Water Provide Project


The Turbidity sensors connect directly to the turbidity controllers which provides a number of benefits over using a turbidity transmitter. Primarily it allows the turbidity controller to re-range the turbidity sensor - which when combined with the OPTU or OLTU sensor - it allows the measuring range to change from 0 - 100 NTU, 0 - 1000NTU or 0 - 4000 NTU as required.


DRFN Lazer Turbidity sensors are used in river and stream gaging, wastewater and effluent measurements, control instrumentation for settling ponds, sediment transport research, and laboratory measurements.


Specification:

Product Name
Lazer Turbidity sensor
Product Model
OLTU602-0MDO1A
Brand Name
Daruifuno
Measuring Range
0.01~100NTU 0.1~50℃
Light Source
660nm laser light source
Accuracy
0.001~40NTU is ±2% of reading or ±0.015NTU take the larger one;
40~100NTU is ±5% of reading
Operating Environment
0~45℃
Flow Rate
100ml/min≤x≤500ml/min
Calibration
Standard solution/water sample/zero point calibration

Working Instructions


OLED window
Sample liquid Level
No judgment
Sample Emptying/Blowdown
Not equipped
Sample Interface
Injection port: 1/4NPT, discharge port: 1/2NPT
Main Material
Body: ABS+Nylon
Dimensions

Length*Wide*Height: 140*117*214mm


Please click the user manual of RS485 turbidity sensor here:

OLTU6 Turbidity sensor.pdf


Features& Advantages

● Adopt 660nm laser light source, high resolution and fast response;
● Can be used in online transmitter, DTU, integrated system;
● Low sampling flow requirements, reducing the amount of waste liquid generated in the measurement;
● The turbidity flow cell can eliminate the interference of air bubbles to the measurement to the greatest extent;
● Optional window and automatic emptying system to reduce maintenance workload;
● Liquid level detection function can automatically determine whether the sample liquid level in the flow cell meets the measurement requirements;
● Stream-style sample track to prevent the sedimentation of suspended solids caused by low flow rates;
● RS485 digital interface, standard Modbus communication protocol, support access to standard industrial control system;
● Internal storage of calibration data, support offline calibration, plug and play on site.

Aplication:

Water treatment monitoring

Drinking water,surface water,water quality analyze,ground water,ect.


Industrial process monitoring and dosing control

Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.


FAQ

Q1. What is the measuring principle of the lazer turbidity sensor?
A: Adopt 660nm laser light source, high resolution and fast response;


Q2. What is the advantage of digital lazer turbidity sensor?
A: The digital turbidity sensor is conducive to long-distance signal transmission without serious signal attenuation. The sensor has RS485 interface, standard Modbus RTU communication protocol.


Q3. Can the Lazer turbidity sensor work under water?
A: Certainly. The protection grade of the turbidity electrode is IP68, it can work under water for a long time and can work under water 40 meters.


Q4. Can customer's logo be added to the turbidity sensor?
Of course, we support OEM services for customers, the sensor can be added to the customer's logo as a sticker.


Q5. Can the turbidity sensor connector be detachable type?

Our turbidity sensor has three options: Undetachable by default, detachablt, wateproof and detachable. Can be flexibly selected according to the needs of the site.


Q6. Can the measurement range of the laser turbidity sensor be 0-50?
Yes, the measuring range of our laser turbidity sensor can be customized.

Quality OLED Window 0.01~100NTU Laser Turbidity Electrode For Water Provide project for sale
Send your message to this supplier
 
*From:
*To: Suzhou Delfino Environmental Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0