Sign In | Join Free | My disqueenfrance.com |
|
Categories | Low profile load cell |
---|---|
Brand Name: | Forsentek |
Model Number: | FHA |
Certification: | CE |
Place of Origin: | China |
MOQ: | 4pcs |
Payment Terms: | T/T,Western Union or Paypal |
Supply Ability: | 9800pcs/month |
Delivery Time: | 1-8 weeks |
Packaging Details: | Carton |
Usage: | Weight transducer |
Type: | Low profile load cell |
Output: | Analog Sensor |
Load direction: | Compression |
Capacity: | 30kg/75kg/150kg/300kg |
Company Info. |
Forsentek Co., Limited |
View Contact Details |
Product List |
Low Profile Compression Load Cell 30kg 75kg 150kg 300kg Thin Weight Sensor
Low profile planar beam load cell FHA is produced based on strain
gauge technology with CE certified. Low profile compression load
cell FHA offers 0-30kg / 0-75kg / 0-150kg / 0-300kg four measuring
ranges to choose form, high accuracy with 0.05% non-linearity of
the full capacity. Thin load cell FHA utilizes 1000ohms gauges
which has better performance compared to commonly used 350ohms
gauges in terms of power consumption and long term stability.
Compact design enables the construction of scales with an extremely
low overall height, affordable load cell FHA is also suitable for
battery powered weighing devices.
Dimensions(in milimeter)
Specifications
Capacity | 30kg / 300N / 66 lb |
Rated output | 1.5/2.0 mV/V |
Excitation | 3-10V |
Zero balance | ±0.1mV/V |
Nonlinearity | ±0.05% R.O. |
Hysteresis | ±0.05% R.O. |
Nonrepeatability | ±0.05% R.O. |
Creep(3min) | ±0.05% R.O. |
Safe overload | 150% F.S. |
Ultimate overload | 200% F.S. |
Operating temperature | -10...+40oC |
Temperature shift zero | ±0.2% R.O./oC |
Temperature shift span | ±0.05% R.O./10oC |
Input resistance | 1120±50 ohms |
Output resistance | 1000±10 ohms |
Insulation resistance | >2000M ohms |
Ingress protection | IP65 |
Material of element | Aluminum alloy |
Cable | 30kg/75kg — 32AWG 400mm 4-wire 150kg/300kg — 32AWG 150mm 4-wire |
Wiring code | Red--Excitation+ Black--Excitation- |
Brief instruction of Rated output(or Sensitivity):
Definition: The signal produced by load cell(or force transducer)
when rated load is applied, expressed in terms of mV/V. The rated
output indicates the output signal range of the sensor.
Sensor output = (Power supply * Rated output) * Load / Capacity
Rated output is normally within 1mV/V~3mV/V.
Power supply is normally within 3-15V.
Load / Capacity is within 0-1.
So the load cell output signal is normally within
0-45mV(-45mV...+45mV for bidirectional load cell).
Example one: Planar beam load cell FHA-30kg with 1.5mV/V rated
output powered by 10V DC ,the output range is 0~15mV.
Example two: Low profile compression load sensor FHA-300kg with
2mV/V rated output powered by 3.3V DC ,the output range is 0~6.6mV.
Load cell zero output:The output signal of the loadcell with
no-load applied,expressed in mV/V or as a percentage of rated
output.The zero output is caused by the stress during strain gauge
bonding,it can be handled during calibration or signal processing
without affecting the measurement accuracy.
Low Profile Load Cell Force Sensor 300N 750N 1500N 3000N Thin Force
Transducer
Click here to download datasheet
![]() |