Sign In | Join Free | My disqueenfrance.com |
|
Categories | Open Loop Hall Effect Current Sensor |
---|---|
Brand Name: | TOKEN |
Model Number: | TKC-TG352 series |
Certification: | CE;ROHS |
Place of Origin: | Nanjing,China |
MOQ: | 10pcs |
Price: | Price reconsideration |
Payment Terms: | L/C, T/T, D/P, Western Union |
Supply Ability: | 10K pcs per month |
Delivery Time: | 7~10 working days |
Packaging Details: | Little carton:34*23*21CM 36pcs/carton;Large carton size 48*37*26CM 72pcs/carton |
Product name: | Hall Effect Current Transformer |
Theory: | Hall sensor |
power supply: | +5V |
Input current: | 20-500A |
offset: | 1/2VCC |
Standards: | UL94-V0 EN60947-1:2004 |
20-500A UL94-V0 Open Loop Programming Hall Effect Current Transformer
Standards
Characteristics chart
The TKC-TG3 series current sensor is a open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of 3 phase DC, AC or pulsed currents.
General date |
Value | Unit | Symbol | |
Operating temperature | -40 to +125 | ºC | TA |
Storage temperature | -40 to+150 | ºC | TS |
Mass(approx) | 99 | g | M |
Electrical data(Ta=25℃±5℃,RL=2KΩ,CL=10000PF) |
Type | TKC 20TG352 | TKC 50TG352 | TKC 100TG352 | TKC 200TG352 | TKC 300TG352 | TKC 400TG352 | TKC 500TG352 | Unit |
Rated current(Ipn) | ±20 | ±50 | ±100 | ±200 | ±300 | ±400 | ±500 | A |
Measuring range(Ip) | ±22 | ±55 | ±110 | ±220 | ±330 | ±440 | ±550 | A |
Rated output | @Ip=±Ipn ±2±1% | V | ||||||
Supply voltage | +5 ±5% | V | ||||||
Power Consumption | ≤15 | mA | ||||||
Offset voltage | ≤±20 | mV | ||||||
Magnetic offset | ±15 | mV | ||||||
Offset drift | @ -40~+85℃ ≤±2.0 | mV/℃ | ||||||
output drift | ±1.0 | mV/℃ | ||||||
Linearity | @Ip=0-±Ipn ≤1 | %FS | ||||||
Response time | @50A/μS, 10%-90% ≤8 | μS | ||||||
Galvanic isolation | @ 50HZ,AC,1min 2.5 | KV |
Applications
Variable speed drives
Welding machine
Battery supplied applications
Uninterruptible Power Supplies (UPS)Electrochemical
Mechanical dimension(for reference only)
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm
Directions for use
Is will be in a forward direction when the Ip flows according to the direction of the arrowhead.
The primary conductor should be≤120℃.
The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with the bus bar.
Characteristics chart
![]() |