Rohde and Schwarz NRT Power reflection meter AC supply
Description of Rohde and Schwarz NRT Power reflection meter
The Rohde NRT is a Power Reflection Meter. Power Reflection Meter
NRT is the right choice: rugged, accurate and compact. Due to the
large variety of measurement functions and high accuracy it is
suitable for classic applications in mobile use as well as for use
in research, development, production and quality management. With
Power Sensors NRT-Z43 and NRT-Z44, the Rohde NRT is tailor-made to
present and future requirements of radiocommunications: the wide
frequency range from 200 (400)MHz o 4 GHz covers all relevant
frequency bands, the measurement method is compatible with all
common analog and in particular digital modulation standards:
GSM/EDGE, 3GPP (W-/TD-CDMA), CDMA (IS-95), CDMA2000, PHS, NADC,
PDC, TETRA, DECT, DAB, DVB-T and many more.The complete range of
sensors of the predecessor model NAP is available for he customary
frequency ranges, eg. shortwave; the sensors can be connected via
an option. Measurement directly on PC While conventional power
sensors can only be used in conjunction with a basic unit, the NRT
family is a step further ahead: the sensors are self-contained
measuring instruments which are able to communicate with the basic
unit or with a PC via a standard serial data interface. Apart from
the possibility of operating the sensor directly at the RS-232 or
PC Card interface of a PC, this concept provides a number of
further benefits: practically maintenance-free basic unit, high
immunity to radiated interference - an important feature for
measurements in he near field of antennas - and remote operation
over very long distances (up to 500 m). Ease of operation With its
large display and a manageable number of clearly laid-out keys,
operation of the NRT basic unit is extremely easy. Switchover
between the main functions is made at a keystroke. Additional
settings are selected in three clearly arranged menus, each of
which can be accessed at a keystroke. A large variety of functions
is available for daily routine measurements: Choice between average
power, average burst power, peak envelope power (PEP)and
peak-to-average power ratio (crest factor) Switchover between
forward power and absorbed power Measurement of power differences
in dB or % Choice between return loss, SWR, reflection coefficient
and reverse-to-forward power ratio in %in reflection measurements
Display of amplitude distribution (CCDF)for modulated signals
Consideration of cable loss between sensor and load Acoustic SWR
monitoring Indication of maximum and minimum values Quasi-analog
bargraph display Choice between measurement at the source or at the
load Summary Power measurement on transmitters, amplifiers,
industrial RF and microwave generators Simultaneous display of
power and reflection Measurement of average power irrespective of
modulation mode Measurement of peak power, crest factor and average
burst power Compatible with all main digital standards, eg.
GSM/EDGE, 3GPP (W-/TD-CDMA), CDMA (IS-95), CDMA2000, PHS, NADC,
PDC, TETRA, DECT, DAB, DVB-T... Intelligent sensors: simply plug in
and go IEC625 (IEEE488)bus and RS-232 interface Digital interface
between sensor and basic unit Direct connection of sensor to a PC
The NRT basic unit comes with an IEC-bus (IEEE488)and RS-232
interface, both to SCPI standard.Three options allow the NRT to be
adapted to different applications: An additional test input allows
the sensors of predecessor model NAP to be connected,thus covering
the frequency range from 200 kHz with power up to 1 kW and above
(NRT-B1) Two additional test inputs for sensors of type NRT-Z
(option NRT-B2)allow monitoring of up to three test points (to be
scanned by manual or remote control) Battery and built-in charger
enable mobile use (NRT-B3)
List of Options
B1 | Interface for NAP-Z power sensors |
B2 | Two rear inputs for NRT-Z power sensors |
B3 | Battery supply with built-in charger and NiMH accumulator |
C3 | Three years of depot calibration coverage based on the R&S
recommended calibration interval - includes test data. The first
calibration is included with product delivery with 1 additional
depot calibrations. |
C5 | Five years of depot calibration coverage based on the R&S
recommended calibration interval - includes test data. The first
calibration is included with product delivery with 2 additional
depot calibrations. |
DCV-1 | Documentation of calibration values |
DCV-ZP | Printout of DCV (additional, in combination with DCV-Option only) |
R3 | Three years of depot repair coverage, including recalibration and
test data if necessary to complete the repair. First year of repair
coverage is provided by the 12-month new product warranty. |
R5 | Five years of depot repair coverage, including recalibration and
test data if necessary to complete the repair. First year of repair
coverage is provided by the 12-month new product warranty. |
Z1 | Accessory: NiMH accumulator |
Z14 | Directional power sensor 25 MHz - 1 GHz 30 mW - 120(300) W,
N-female |
Z2 | 10 meters extension cable for NRT-Z power sensors |
Z2 | 30 meters extension cable for NRT-Z power sensors |
Z3 | RS232 interface adapter for NRT-Z power sensors Including AC power
supply |
Z4 | PCMCIA interface adapter for NRT-Z sensors |
Z43 | Directional power sensor 0.4 - 4 GHz, 7 mW - 30(75) W N-female |
Z44 | Directional power sensor 200 MHz - 4 GHz, N female, |
Z5 | USB Interface Adapter for NRT Power Sensors |



FAQ:
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual
delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .