| 015 | 6 GHz return-loss Measurement Accessory Kit |
| 045 | Millimeter Wave Accessory |
| 071 | Digital Demodulation H/W for S/N USUS4142/MY4140 Changed to B7J on
newer models |
| 0B0 | Do not include manuals |
| 0B1 | Add Manual Set |
| 0BV | Service Documentation, Component Level |
| 0BW | Service Documentation, Assembly Level |
| 107 | Audio input 100 kOhm |
| 110 | RF/uW internal preamplifier |
| 111 | USB device side I/O interface |
| 115 | 512 MB user memory |
| 117 | Secure memory erase |
| 119 | Noise Figure Hardware Kit. Standard on all models S/N >
US4222/MY4100. |
| 122 | 80 MHz bandwidth digitizer |
| 123 | Switchable MW Preselector Bypass |
| 124 | Y-axis video output |
| 140 | 40 MHz bandwidth digitizer |
| 1A7 | PSA Series ISO 17025 compliant calibration with test data |
| 1CM | Rackmount Kit |
| 1CN | Handle kit |
| 1CP | Rack mount kit with handles |
| 1CR | Rack slide kit |
| 1DS | RF internal preamplifier |
| 202 | GSM w/edge measurement personality |
| 204 | 1xEV-DO Measurement Personality |
| 210 | HSDPA/HSUPA measurement personality |
| 211 | TD-SCDMA measurement personality |
| 212 | TD-SCDMA Modulation Analysis Measurement Personality |
| 213 | HSPA/8PSK for TD-SCDMA Modulation Analysis Measurement Personality |
| 214 | 1xEV-DV measurement personality |
| 215 | External Source Control Measurement Personality |
| 217 | WLAN Measurement Personality |
| 219 | Noise figure measurement personality |
| 226 | Phase noise measurement personality |
| 230 | Benchlink web remote control software |
| 233 | Built-in measuring receiver personality |
| 235 | Wide BW digitizer external cal wizard |
| 239 | EMC measurement personality |
| 23A | AM/FM/PM triggering for measuring receiver |
| 23B | CCITT filter for audio measurements |
| 241 | Flexible digital modulation analysis |
| 266 | Programming code compatibility suite measurement personality |
| 423 | Switchable Microwave Preselector Bypass. Available for all models
with S/N |
| 426 | Gated Sweep Hardware. Standard on all models >S/N US/MY4336. |
| 515 | Attenuator to RF Cable |
| 516 | 40 MHz BW IF output - low band |
| 517 | Boris DIF --with opt 122 or 124 |
| 518 | Natasha DIF -- no opt 122 or 124 |
| 520 | Preselector bias cable - no opt HNQ |
| 627 | Required for all options except HT1 |
| 628 | Required for all options except 111 |
| 629 | Required for 110 or 123 or 110 with 123 |
| 630 | Required for option 110 without 123 |
| 631 | Required for 123 without 110 |
| 632 | Required for option 110 with 123 |
| 633 | Required for all options except HS1, HS7 and HT1 |
| 701 | Delete TV Sync. Trigger Capability, Fast Time Domain Sweeps, AM/FM
Demodulator and Analog + Display |
| 903 | POWER CORD |
| A6J | PSA Series ANSI Z540 compliant calibration with test data |
| AB1 | Korea Quick Users Guide (Korean localization) |
| AB2 | China Quick Users Guide (Chinese localization) |
| ABA | U.S. Quick Users Guide (English localization) |
| ABD | Germany Quick Users Guide (German localization) |
| ABE | Spain Quick Users Guide (Spanish localization) |
| ABF | France Quick Users Guide (French localization) |
| ABJ | Japan Quick Users Guide (Japanese localization) |
| ABZ | Italy Quick Users Guide (Italian localization) |
| ANE | 64 MB Flash Ram Memory. Shipped Standard on all 46A/47A/48A Models.
Shipped Standard on all models >US/MY4222 |
| ATP04 | ATP LEADTIME ITEM FOR E4446A-H7L |
| ATP05 | ATP LEADTIME ITEM FOR E4446A-HB2 |
| ATP06 | ATP LEADTIME ITEM FOR E4446A-HGT |
| ATP07 | ATP LEADTIME ITEM FOR E4446A-HN9 |
| ATP08 | ATP LEADTIME ITEM FOR E4446A-JMP |
| AYZ | External mixing |
| B78 | CDMA2000 Measurement Personality |
| B7J | Digital demodulation hardware |
| BAB | 3.5 mm RF input connector |
| BAC | CDMAOne Measurement Personality |
| BAE | NADC,PDC Measurement Personality |
| BAF | W-CDMA Measurement Personality |
| H25 | 25 MHz IF Output |
| H26 | High Band Preamplifier (Discontinued) Replaced by option 110. |
| H47 | E4446A-H47 is a temporary option to pre-order the E4447A for export
to China. |
| H70 | 70 MHz IF Output |
| H7L | Auxiliary Wideband Log Video Output |
| HB2 | 21.4 MHz IF Output |
| HB6 | Prevent Unauthorized F/W upgrade |
| HBA | Rear Panel RF Input |
| HN8 | Wideband Preselector Bypass (No Preselector) |
| HN9 | 80 MHz wide baseband IF output at 321.4 MHz for frequencies less
than 3.05 GHz |
| HNQ | I/Q Front Panel Output connectors with hardware for use with
89600A. |
| HS1 | Increase level of security write protects to user files |
| HS7 | Security erase software |
| HT1 | GPS Interface Card for Trimble GPS |
| HX4 | 140 MHz IF output on rear panel |
| HY7 | Improved Gain 70 MHz IF Output |
| JMP | Rear panel jumper cable |
| N6171A | MATLAB Software |
| N6171A-M01 | MATLAB - Basic Package |
| N6171A-M02 | MATLAB - Standard Package |
| N6171A-M03 | MATLAB - Advanced Package |
| N9051A | Pulse measurement software |
| N9051A-2FP | Pulse measurement software, fixed, perpetual, license |
| N9051A-3FP | Phase & Frequency Measurements |
| N9051A-4FP | Extended Analysis & Statistics |
| PS-S20-01 | Recommended Startup assistance |
| R-50C-001 | Standard Calibration w/data. Replaced UK6 |
| R-50C-002 | Traceable Calibration standards compliant initial receipt.
(ANSI-Z540/17025) |
| R-50C-011-3 | Agilent Calibration - 3 years |
| R-50C-011-5 | Agilent Calibration - 5 years |
| R-50C-016-3 | ISO 17025 Compliant Calibration - 3 years |
| R-50C-016-5 | ISO 17025 Compliant Calibration - 5 years |
| R-50C-021-3 | ANSI Z540-1-1994 Calibration - 3 years |
| R-50C-021-5 | ANSI Z540-1-1994 Calibration - 5 years |
| R-51B-001-3C | Return to Agilent Warranty - 3 years |
| R-51B-001-5C | Return to Agilent Warranty - 5 years |
| R-51B-001-C | Return to Agilent Warranty - 1 year |
| R-52A-001-3 | 3 Year Calibration License (Commercial) |
| R-52A-001-L | Lifetime Calibration License (Commercial) |
| R-52A-002-3 | 3 Year Calibration License (Z540/17025) |
| R-52A-002-L | Lifetime Calibration License (Z540/17025) |
| RMKT | Agilent Refurbished Product (Do Not Use - Certiprime Option) |
| UE2 | Firmware Kit. CD-ROM. |
| UK6 | Commercial Cal Certificate with Data |