Sign In | Join Free | My disqueenfrance.com
disqueenfrance.com
Products
Search by Category
Wholesale Marketplace
Home > Energy Meters >

Portable Three Phase Electric Meter Calibration Equipment 0.05% Accuracy Class

Categories Electric Meter Calibration
Brand Name: GFUVE
Model Number: GF302D
Certification: CE,ISO9001:2008,IEC approved
Place of Origin: Beijing China
MOQ: 1Set
Price: US$12000~US$14000/Set
Payment Terms: Western Union, T/T
Supply Ability: 45Sets
Delivery Time: 17days after receipt of payment
Packaging Details: Aluminium alloy box
GF302D: Portable Three Phase kWh Meter calibration equipment
Accuracy class: 0.05% 0.1%
Communication port: RS485 port
Display: 7-inch TFT color display touch screen
Display language: English version display
Current output: 120A Max
Voltage range: 0~500V
Characteristics: Portable type
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Portable Three Phase Electric Meter Calibration Equipment 0.05% Accuracy Class


GF302D Portable Three Phase kWh Meter calibration equipment, with accuracy class of 0.05%,


high stability, english version display, two years quality warranty.

(Accuracy class 0.05%/0.1%)


Application


The Portable Three Phase kWh Meter calibration equipment is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high precision standard power source.


Features


Able to test basic error, shunt running, start, standard error automatically and manually in single-step of single/three phase, according to relative regulation of kWh meter.

Able to do change test caused by voltage influence, frequency influence and harmonic influence.

Output of power source is speedy and stable, AC maximum output of each phase can reach 120A in maximum.

Voltage, current and phase position of each phase can be adjusted in split-phase, improving the flexibility of power source.

Frequency of each impulse input port can reach 40Hz.

7-inch TFT color display touch screen, English menu, simple and convenient operation, commonly used functions and current basic load point can be controlled in one button.

Each meter position can provide one standard, dependent RS485 port, and able to perform multi-function test, such as communication test.

Impulse port of each meter position, external polarity can be set randomly, able to adapt kWh meter of impulse cascade and common-anode.


Electrical parameters 
Accuracy0.05%, 0.1%
Power SupplyOne Phase AC 180-265V, frequency 50/60Hz.
AC Voltage Output 
Range(U1,U2,U3)57.7V, 100V, 220V, 380V
or 69.3V, 120V, 240V, 480V( optional)
Adjustment range(0-120)%RG(1)
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability0.01%/120s
Distortion0.3% (Non-capacitive load)
Output loadeach phase 25VA
Measuring accuracy0.05%RG
AC Current Output 
Range(I1,I2,I3)200mA, 1A, 5A, 20A, 100A
Adjustment range(0-120)%RG
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability<0.01%/120s
Distortion≤0.3% (Non-capacitive load)
Output load45VA
Accuracy0.05%RG
Power Output 
Active power output stability<0.01%RG/120s
Reactive power output stability<0.02%RG/120s
Active power measuring accuracy0.05%RG
Reactive power measuring accuracy0.1%RG
Phase Output 
Output adjustment range0°-359.999°
Output adjustment fineness10, 1, 0.1, 0.01 as optional.
Resolution0.01°
Accuracy0.05°
Power Factor 
Adjustment range-1 ~ 0 ~ 1
Resolution0.0001
Measurement accuracy0. 0005
Frequency Output 
Adjustment range45Hz-65Hz
Output adjustment fineness5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution0.001Hz
Accuracy0.005Hz
Voltage /Current/Harmonic Setting 
Harmonic number2-51times
Harmonic content0-40%
Harmonic phase0-359.99
Harmonic setting accuracy(10%±0.1%)RD(2)
Power Energy Measurement Error 
Active power energy0.05%RG
Reactive power energy0.1%RG
Power Pulse Output 
Power pulse typeactive pulse, reactive pulse
Active power pulse output5V, 10mA
Power Pulse Input 
Energy pulse typesupport active and reactive pulse, the highest frequency power pulse input is 180K.
Mechanical parameters 
Dimensions (W×D×H) (mm)500x600x175
Weight (kg)About 27
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.

Quality Portable Three Phase Electric Meter Calibration Equipment 0.05% Accuracy Class for sale
Send your message to this supplier
 
*From:
*To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0