Sign In | Join Free | My disqueenfrance.com |
|
Categories | Flow Controller |
---|---|
Brand Name: | Consensic |
Model Number: | CAFS6000 |
Certification: | PTC22072602101C-CN01 |
Place of Origin: | WUXI |
MOQ: | Please contact us for details |
Price: | Offline contact or face-to-face discussion can be negotiated |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram/Alipay/business-to-business |
Supply Ability: | 1000 |
Delivery Time: | 3-7 work days |
Maximum operating temperature range: | -15°C to + 70°C |
response time: | 9~500ms customizable |
Flow range: | 0~10000sccm Customizable specifications |
accuracy: | 2%FS |
Calibration conditions: | 0℃, 1 standard atmosphere |
Maximum voltage output: | 4.96 ~5.02V linear |
Company Info. |
Wuxi Consensic Electronic Technology Co., Ltd. |
Verified Supplier |
View Contact Details |
Product List |
Fit & Install
Ensure that the sensor is undamaged and the wiring is complete.
During installation and connection, ensure that the airflow
direction aligns with the sensor's airflow indication direction,
and connect the sensor lead line correctly based on the definition.
After confirming the correct connection, proceed to connect the
power supply to initiate operation.
For optimal accuracy, it is recommended to preheat the sensor for 2
minutes before use by connecting it to the power supply.
Performance Metrics
Test conditions: Vin = 12±0.1VDC, Ta=25°C. Relative humidity: 40%
<relative humidity <60%.
Maximum operating temperature range: -15°C to +70°C Specifications:
CAFS6000 Series Least Value | Normal Value | Crest Value | Unit |
Remarks Flow Range | 0 | 10000 | sccm | Customizable specifications
Service Voltage | 8-24V | V | Customizable Current | 50 | mA
Maximum Voltage Output | 4.96 | 5 | 5.02 | V | Linear Zero Point
Voltage Output | 0.98 | 1 | 1.02 | V | Linear Accuracy | 1.5 | 2 |
%FS Repetitiveness | ±0.3 | %
Resolution Ratio | 0.1 | % gamut Withstand Voltage | 0.3 | 0.5 |
MPa | Customizable Response Time | 9 | 65 | 500 | ms | Customizable
Zero Drift | 0.2 | %Year gamut Calibration Conditions | 0℃, 1
standard atmosphere Overall Material | Silicon carbide, epoxy
resin, PPS, and silicon are used as sealing materials.
Maximum Rating
■ Operating temperature: -15°C to 70°C
■ Storage temperature: -25°C to 85°C
■ Humidity: 0100% RH *
■ 100 g
■ The sensor is resistant to condensate water
![]() |