High Temperature Liquid Flush Diaphragm Pressure Sensor for Food and Healthcare Industries

Categories Flush Diaphragm Pressure Sensor
Brand Name: HT SENSOR
Model Number: BP93420-IQT
Certification: ISO9001
Place of Origin: Baoji,China
MOQ: 1
Price: Negotiable
Payment Terms: Western Union, L/C, T/T
Supply Ability: 5000PCS/Month
Delivery Time: 5-8 work days
Packaging Details: Standard Export Package
Model NO.: BP93420-IQT
Thread: 50.4mm
Pressure Type: Gauge , Absolute Pressure ,Sealed Pressure
Transport Package: Carton
Specification: Silicon pressure sensor transmitter
HS Code: 9026201090
Type: flush diaphragm Pressure sensor Transmitter
Accuracy Grade: 0.5%F.S
Pressure range: -100kpa...0kpa ~35kpa...3.5MPa
Output: 4-20mA and so on
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

High Temperature Liquid Flush Diaphragm Pressure Sensor for Food and Healthcare Industries

Food And Healthcare Industries Flush Diaphragm Pressure Sensor For High Temperature Liquid

BP93420-IQT Pressure Transmitter

Introduction of flush Diaphragm pressure sensor:


The BP93420-IQT flat membrane pressure sensor utilizes an elastomer made from imported materials, along with diaphragm isolation technology. Importantly, the sensor head has no pressure sensing holes, eliminating the risk of non-viscous medium blockage during measurement. This integrated design makes the transmitter suitable for pressure measurement and control applications involving viscous media such as chemical coatings, paint, mud, asphalt, and crude oil.


Hengtong Clamp OEM Flush Membrane Pressure Transmitter
Hengtong Clamp OEM Flush Membrane Pressure Transmitter
Hengtong Clamp OEM Flush Membrane Pressure Transmitter
Performance Parameters of flush Diaphragm pressure sensor:
Measurement Range-100kPa…0kPa ~ 35kPa…3.5MPa
Pressure TypeGauge Pressure, Absolute Pressure, Sealed Pressure
Overload≤ 1.5 times of the rated range
Accuracy @ 25ºC±0.25% (Typical) ±0.5% (Maximum)
Repeatability≤0.1%FS
Hysteresis≤0.1%FS
Long-Term Stability±0.1%F.S/Year(Typical) ±0.2%F.S/Year(Maximum)
Zero Point Temperature Drift±0.02%F.S/ºC(≤100KPa) ±0.01%F.S/ºC(>100KPa)
Full Scale Temperature Drift±0.02%F.S/ºC(≤100KPa) ±0.01%F.S/ºC(>100KPa)
Frequency Response2.4Khz
Compensation Temperature0-70ºC(customizable)
Operating Temperature-20ºC~80ºC
Storage Temperature-40ºC~120ºC
Vibration10g,55Hz ~ 2kHz
Housing Material304,316L
Diaphragm Material316L
Insulation Resistance100MΩ 100VDC
Protection RatingIP65
Weight~0.3kg



Product Features of flush Diaphragm pressure sensor:


1. Wide measurement range,Various pressure interface options.

2. Diverse output signal options.

3. Adjustable zero and full-scale.

4. High accuracy,multiple sterile process connections.



Applications of flush Diaphragm pressure sensor:


1. Suitable for measuring non-corrosive gases and liquids with 316L.

2. Medical, biopharmaceutical, and food hygiene industries for sterile processing.

3. Used in the paper and chemical industries, as well as for sewage level and beverage can pressure measurements Suitable for hydraulic and pneumatic control systems.


Output SignalSupply VoltageOutput Type
4~20mA12~30VDC2/3/4 wire
0~10/20mA
3 wire
0/1~5V
0/1~10V
0.5~4.5V5VDC
RS485 Communication Protocol3.6~30V / Battery4 wire





Hengtong Clamp OEM Flush Membrane Pressure Transmitter







Hengtong Clamp OEM Flush Membrane Pressure Transmitter

Ordering tips

1. Media Compatibility
When selecting a product, ensure the media under measurement is compatible with the wetted components of the sensor. This compatibility is crucial for the reliable and proper functioning of the device.

2. Explosion-Proof Products
Please note that explosion-proof products do not include a digital display as standard when placing an order. This is an important factor to consider if a digital display is required for your application.

3. Grounding and Lightning Protection
To guarantee the reliable operation of the product, we recommend installing lightning protection devices on-site and ensuring the proper grounding of both the product and power supply. This will help safeguard the sensor against electrical disturbances, maintaining consistent performance.

4. Cable Options
The product does not come with a default attached cable. If a cable is needed, there are three material choices available: polyethylene, PVC, and armored. Unless otherwise specified, the polyethylene cable option will be used by default. If you require a different cable material, please indicate this in your order form.

5. Special Requirements
For applications with special requirements, such as strong vibration, instantaneous impact force, or intense electromagnetic/radio frequency interference, please inform us and provide the details in your order. This will allow us to verify the product's suitability for your unique application needs.


Order Guide of flush Diaphragm pressure sensor
BP93420XXPressure Transmitter
CodeOutline Construction
IBGeneral Pressure TransmitterIXDisplay Pressure Transmitter
IEShock-resistant Aviation Pressure TransmitterIIC/IIIIndustrial General/ Display Pressure Transmitter
IFMoisture-proof Pressure TransmitterIIE/IIIEGeneral/Display Pressure Transmitter
INAir Conditioning Dedicated Pressure Transmitter
ICHigh-temperature Pressure Transmitter
IQ1/IQ2Large Diaphragm /High-temperature Pressure Transmitter
Measurement Range-100kPa…0kPa ~ 35kPa…3.5MPa
(0-X)Kpa or MPaX: Indicates the Actual Measuring Range
CodePower Supply
D124VDC
D25VDC
D3Other
CodeOutput Signal
S14~20mADCS50~20mADC
S21~5VDCS60~10VDC
S30~5VDCS70.5~4.5VDC
S40~10mADC
CodePressure Connection
J1M20×1.5
J2G1/2
J3G1/4
J47/16-20UNF
J5Other
CodeElectrical Connection
B1Hirschmann
B2PG7 Plug
B3Sealed Cable Output
B42088 Industrial Casing
B52088 Industrial Casing with Display
B6Other
CodePressure Type
GGauge Pressure
AAbsolute Pressure
SSealed Reference Pressure



FAQ:

Q&A

Q1:Areyou manufactrade company?

A1:We are manufactrader with more than 29 years of experience.


Q2:Customized Product

A2:We provide OEM and Custom-Design services.


Q3:Quality Quarantee

A3:Our products have a limited 12 to 18 months warranty from shipment date to the original purchaser.Hengtong will replace or repair defective products free of charge.This warranty does not apply to any units have been modified,misused,neglected.


Q4:Shipment&packing

A4:Products are generally shipped by international Express including UPS,FedEx,DHL and INT for freight prepaid,also can use your shipment account to collect,Standard export packing,including inspection certification.


Q5:Contact US

A5:We have an active and experienced sales team to serve you on technical question and business issue.Just leave us message or click the Online Service.


Hengtong Clamp OEM Flush Membrane Pressure Transmitter

Quality High Temperature Liquid Flush Diaphragm Pressure Sensor for Food and Healthcare Industries for sale
Send your message to this supplier
 
*From:
*To: Baoji Hengtong Electronics Co., LTD
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0