LCD Display HbA1c Test Equipment High Performance Liquid Chromatography Color

Categories HPLC HbA1c Analyzer
Brand Name: LABNOVATION
Model Number: LD-560
Certification: IFCC, NGSP, CE
Place of Origin: Shenzhen, China
MOQ: 1 Unit
Price: USD7,000.00-12,000.00/Unit
Supply Ability: 100 Units/Day
Delivery Time: 15-20 working days
Packaging Details: Carton Size: 480mm×480mm×615mm, Gross Weight: 28kgs
Principle: HPLC (High Performance Liquid Chromatography)
Test Speed: 90s/test
Sample types: Whole blood or Pre-diluent sample
Test blood volume: 5μL in whole blood mode 150μL in pre-diluted mode
Sample capacity: 20 samples
Sample loading method: Continuous automatic sample loading
Column test quantity: 3000
Reagent pack: 600T(Reagent)/ 3000T(Column) separate
Eluent Kind: 2 kinds
Data storage: 5000
Built-in Thermal Printer: Yes
CV: <2%
Test range: 3.0%~18.0%
Operation screen: 10 inch Full color LCD display
Weiht: 28kg
Dimensions: 378(L) ×380(W)×510(H)mm
Shelf Life: 5 years
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

LCD Display HbA1c Test Equipment High Performance Liquid Chromatography Color

High Performance Liquid Chromatography Color Lcd Display Hba1c Analyzer


Intended use
The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.The positioning of our instrument is for institutions with 10-30 daily samples, our instrument is a light rapid test equipment. The instrument weighs only 25kgs, the detection speed is 90s/test with a 10“ large LCD touch screen.
Principle
Glycosylation of hemoglobin results in a loss of surface cations that are uncharged, and non-glycosylated hemoglobin is positively charged.

According to the different charged properties of hemoglobin, several hemoglobin components including HbA1c were separated by high performance liquid chromatography using cleaning solutions of different pH values and ionic strengths. The stationary phase used is a weakly acidic cation exchanger.

The mobile phase in the solution reservoir enters the injector via the HPLC pump, where it is mixed with the sample.Each component of the mixture passes through the chromatographic column at different rates, and each component flows out of the chromatographic column sequentially due to the different adsorption capacities between each component and the stationary phase in the chromatographic column.Then, the component concentration is converted into an electrical signal and transmitted to the HPLC software of the computer, and the generated waste liquid enters the waste liquid bottle. After the operation is completed, the chromatogram can be obtained in the HPLC software.

Specification


InstrumentManufacturerLanovation
Manufacture placeChina
ModelLD-560
Dection informationPrincipleHPLC
Detection methodDual wavelengh colorimetry
Wavelength420nm
Test time90 Seconds
Test Speed throughtput40 samples per hour
Sample informationSample typesWhole blood or Pre-diluent sample
Test blood volume5μL in whole blood mode
150μL in pre-diluted mode
Sample capacity20 samples
Sample loading methodContinuous automatic sample loading
MixerNo, but probe mixing samples
Reagent and other consumbleColumn test quantity3000
Reagent pack600T(Reagent)/ 3000T(Column) separate
Eluent2
Operation and character informationOperation screen10 inch Full color LCD display
Data storage5000
Built-in Thermal PrinterYes
Performance informationCV<2%
Test range3.0%~18.0%
 
Package Information
Dimensions378(L) ×380(W)×510(H)mm
Weight28kg

Product Composition

Main Parts

The analyzer consists of an auto sample injection module, a liquid chromatography separation module, a colorimetric detection and control module, a barcode scanning module, and a display printing module.



Reagents and Consumables

The analyzer is recommended to be used in conjunction with the Glycosylated Hemoglobin Test Reagent Kit (high performance liquid chromatography (HPLC method)) produced by our company, which includes the following components:
Eluent A/Eluent B/Eluent C(Variant Mode)Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non glycated hemoglobin.
Hemolysis ReagentUsed to dissolve red blood cells and release hemoglobin.
Chromatography ColumnUsed for separation and elution of glycosylated hemoglobin and non glycated.
Hemoglobin FilterUsed to initially filter the sample after hemolysis.
Paper RollsPrints a report of the test results.