High Performance Liquid Chromatography Automated HbA1c Analyzer For Glycosylation Hemoglobin Detection

Categories HPLC HbA1c Analyzer
Brand Name: LABNOVATION
Model Number: LD-560
Certification: IFCC, NGSP, CE
Place of Origin: Shenzhen, China
MOQ: 1 Piece
Price: US$5000-12000/Piece
Payment Terms: D/A, D/P, T/T
Supply Ability: 100 Units/Day
Delivery Time: 5-7 work day
Packaging Details: Carton
Method: HPLC (High Performance Liquid Chromatography))
CertificatedWaveLength: 420nm
Sample Capacity: 20 Samples
Parameters: HbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional)
Certificate: NGSP, IFCC, CE
Working Condition: Temperature: 15-30℃ Humidity:30%-85%
Voltage: 100-240VA
Report Range: 3-18%
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

High Performance Liquid Chromatography Automated HbA1c Analyzer For Glycosylation Hemoglobin Detection

LD-560 HPLC System for HbA1c Testing


The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin

(HbA1c) in human blood.



Performance Parameteras


Reporting unit: Glycosylated hemoglobin (HbA1c) is reported in NGSP (%) and IFCC units (mmol/mol).
Accuracy: The accuracy is tested with reference materials as samples, and the relative deviation of the
test results should be within ± 5%.
Repeatability: For samples with a test concentration of 4% 6%, the sample coefficient of variation (CV)
of the test results is not greater than 2.0%.
Linear range: Within the range of 3% 18% of glycosylated hemoglobin, the linear correlation coefficien t
R value of the test results should not be less than 0.9900.
Stability: Within 8 hours after the analyzer is turned on and stabilized, the same normal sample is tested, and the relative deviation of the test results is not more than ±3.0%.
Carrying pollution: The carrying pollution rate of the analyzer should not be greater than 2.0%.
Basic function: Provides Chinese report and abnormal alarm.

The temperature accuracy and fluctuation of the chromatography column module: the temperature is within ±1°C of the set value, and the fluctuation is not more than 0.8°C.